Refilling Solvent; Filling The Slimsorba Carbon Container (Optional Equipment) - BÖWE P25 Instruction Manual

Hide thumbs Also See for P25:
Table of Contents

Advertisement

6
Operation
To fill without emissions, proceed as follows:
-
Remove the screw cap on the pump line.
-
Connect a hose between the barrel and pump suction side.
-
Connect gas displacement line between the barrel and water separator.
-
Open the ball valve.
-
Start program P44.
-
The tanks fill up, with one overflowing into the other.
-
Watch the level of the liquid in the tanks and stop program P44 when the tanks are full.
-
Close the ball valve.
-
Remove the connecting lines to the barrel.
-
Screw the cap back on to the pump line.
-
Remove the gas displacement line.
With c and o combinations:
-
First fill the c machine with P44
-
Next start P61 on the o machine in order to fill it.
-
Then start P44 on the c machine again.
6.1.3

Refilling Solvent

Follow the procedure given in Point 6.1.2 for routine refilling of solvent.
Attention: Even empty containers can still hold solvent residues.

6.1.4 Filling the Slimsorba Carbon Container (Optional Equipment)

-
Loosen the upper pipe flange on the carbon container.
-
Loosen the quick release fastener on the cover and remove cover.
-
Remove fine filter sieve and clamping ring.
-
Fill in 12 kg (22 lb) of activated carbon (cylindrical pellets with approx. 4 mm (0.16 inch) diameter,
type Supersorbon K40). The heating coil must be covered.
-
Replace the fine filter sieve and clamping ring.
-
Replace the cover and close the quick release fastener.
-
Secure the upper tube of the carbon container again.
Therefore tightly seal the container (barrel) again and
store or dispose of in accordance with regulations!