10 Operating and Monitoring Systems

1
Filter pressure gauge
2
Sight-glass, filter circuit:
3
Sight-glass, refrigeration unit
4
Cooling water regulator, distillation 19 Overfill sensor, safety separator
5
Cooling water regulator,
refrigeration unit
6
Low cooling water level switch
7
High pressure control switch
(refrigerating):
8
Low pressure control switch
(refrigerating):
9
Low pressure gauge (refrigerating) 24 Distillation overfill preventer
10 High pressure gauge
(refrigerating)
11 Low air pressure switch
12 Compressed air display (pressure
gauge)
13 Drying controller
14 Pushbutton, dosing unit
15 Dosing pump for antifoaming agent
/neutralization agent
35
16 Dosing unit
17 Sensor, high level
18 Sight-glass, safety separator
20 Sight-glass, still
21 Water drain valve
22 Sight-glass, water separator
23 Sight-glasses, inlet to water separator
Additional operating and monitoring systems:
-
Sensor, solvent detergent solution
-
Sight-glasses tanks 1, 2 + 3 (front side):
-
Overfill sensor, disposal vessel
10