Operation
6.1.8

Spraymatic (Optional Equipment)

The SPRAYMATIC SPP draws the product out of a tank and sprays it onto the garments in the cage.
Insert suction hose into cleaning agent container.
-
For the rest of the procedure, refer to the SPRAYMATIC SPP instruction manual.
-
If the SPP is idle for a longer period of time (e.g., over the weekend), perform the rinsing procedure
before starting program P42.
6.1.9

Opening the Loading Door

Never leave the loading door standing open!
Before each start, make sure that the loading door is closed.
During longer standstills, concentrations of the solvent gas can form. For this reason, the machine
control system has been designed to lock the loading door after a standstill of 1 minute.
You can unlock the door with the " ⇑ " button for up to 9 minutes.
After 10 minutes, you cannot open the loading door until after you have started the "DEODORIZING"
program (P34) and the horn has stopped sounding.
Once the machine has been turned on, it is not possible to open the loading door until the
"deodorizing" program (P34) starts and the horn sounds to signal the end of the program.
Attention: When neither current nor compressed air is present or
Caution
The trained user is permitted to carry out an EMERGENCY opening only when the program has stopped
and the cage is not turning. Open the button trap cover before the emergency opening.
After removing garments that have not finished drying, place them in a solvent-tight transport container.
Follow safety regulations (wear protective gloves, room ventilation, etc.).
Emergency release
There is an 8-mm (.3 in) ∅ bore hole in the paneling, to the left of the loading door, that you can use to
release the lock.
Use a screwdriver to press the bolt to the left and open the loading door.
After correcting the error, close the loading door and cover and continue the program by pressing the
"Start" button.
when the program has been interrupted, a mechanical
EMERGENCY opening is possible.