Advertisement

Quick Links

DF5(X)00HD-DN
Commissioning
English
005309 / 1.0.7 / 2018-12-14

Advertisement

Table of Contents
loading

Summary of Contents for dallmeier DF5 Series

  • Page 1 DF5(X)00HD-DN Commissioning English 005309 / 1.0.7 / 2018-12-14...
  • Page 2 Mozilla and Firefox of Mozilla Foundation headquartered in Mountain View, California, USA. Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the com- plete identification of third-party trademarks and indication of the respective holder of rights.
  • Page 3: Table Of Contents

    4 Safety Instructions 5 General Notes Scope of Delivery Transportation and Packaging Warranty Approvals/Certifications Appropriate Use Operation 6 Requirements Ambient Conditions Power Supply 7 Maintenance 8 Installation 9 Pin Assignment 10 Connection and Login Connection Login 11 Technical Specifications 12 Dimensions www.dallmeier.com...
  • Page 4: Validity

    Always follow the instructions, notes and warnings and observe the technical specifications in the product data sheet. Keep all documents in legible condition and in a suitable location for future refer- ence. Regularly check the website www.dallmeier.com for the latest updates on product documentation. www.dallmeier.com...
  • Page 5: This Document

    The document “Data Sheet” contains detailed technical specifications, features and characteristics of the device. The target audience of the document is trained system integrators. Configuration The document “Configuration” contains detailed descriptions on the configuration of the device. The target audience of the document is trained system integrators. www.dallmeier.com...
  • Page 6: Typographical Conventions

    WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.  CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. www.dallmeier.com...
  • Page 7 “Expressions” in quotation marks generally indicate a control element on the device (switches or labels) or on its user interface (buttons, menu items). Paragraphs in italics provide information on basic principles, special features and efficient procedure as well as general recommendations. www.dallmeier.com...
  • Page 8: Safety Instructions

    • System Components Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components may cause malfunctions, damages and data loss and may result in the loss of warranty.
  • Page 9 To avoid damage to the device by electrical surge during lightning storms, all protective measures, which are specified by the currently valid DIN, VDE and ISO standards and which provide for a standard-compliant lightning protection equipotential bonding, are mandatory and must be fulfilled by all means. www.dallmeier.com...
  • Page 10 The device may only be opened by qualified personnel for inspection, mainte- nance and repair. • Disposal Do not dispose waste electrical and electronic equipment into the household trash. Disconnect the device from the power supply. Remove all connected devices. Return the device to your respective sales partner. www.dallmeier.com...
  • Page 12: General Notes

    Transportation and Packaging Store the original packaging for later transportation. Dallmeier is not responsible for any damage resulting from unprofessional/im- proper transportation. The device should only be shipped in the original packaging. If the original packaging is no longer available, ensure that the used packaging suf- ficiently protects the device against damage, moisture, heat and cold.
  • Page 13: Warranty

    The following approvals/certifications were valid for the device at the time of this document’s compilation: • CE, FCC, RCM, UL, DIN 50130-4 compliant Visit www.dallmeier.com for possible updates. Note (USA) This equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to Part 15 of the FCC Rules.
  • Page 14: Appropriate Use

    In this case, it is absolutely necessary to use a ventilated, temper- ature-controlled weather-proof metal housing and a sunshield, where required. In addition, a metal slide should be used if the camera is installed in a (weather-proof) housing to ensure optimal heat dissipation. www.dallmeier.com...
  • Page 15: Operation

    • The accuracy of the automatic white balance (AWB) algorithm depends on the used lighting. Mixed light (consisting of artificial light and daylight) may cause color distortions (inaccurate color reproduction). • Poor lighting can lead to an incorrect white balance. www.dallmeier.com...
  • Page 16: Requirements

    • with strong heat emissions (e.g. radiator), • with improper ambient temperatures, • near sources with strong radiation (e.g. radio transmitters, magnetic fields), • with corrosive surroundings (e.g. gases, salt water), • with insufficient air ventilation (e.g. closed cabinet). www.dallmeier.com...
  • Page 17: Power Supply

    NOTICE Damage to the device resulting from improper power supply ➡ Always ensure the correct polarity when using a separate power supply unit. ➡ Do not use PoE (Power over Ethernet) and a separate power supply unit simultaneously. www.dallmeier.com...
  • Page 18: Maintenance

    • Always beware not to touch the lens element in order to avoid damages due to scratching or loss of image quality due to fingerprints. • Do not use canned air. • Do not use organic solvents (alcohol, benzine) or cotton buds for cleaning. www.dallmeier.com...
  • Page 19: Installation

    ➡ For the installation of ceiling/wall brackets, always use screws and anchors suitable for your ceiling/wall type: • Plastic screw anchors for solid wall material (concrete/brick) • Toggle-bolt-style anchors for drywall/hollow wall type (plaster) You need: • Ceiling/wall bracket with tripod screw (1/4"-20 UNC) www.dallmeier.com...
  • Page 20 DF5(X)00HD-DN Commissioning ❶ ⓐ ⓐ Tripod socket UNC 1/4"-20 for brackets with standard tripod screws www.dallmeier.com...
  • Page 21 Commissioning DF5(X)00HD-DN ⓐ ⓐ Tripod socket UNC 1/4"-20 for brackets with standard tripod screws www.dallmeier.com...
  • Page 22 DF5(X)00HD-DN Commissioning ❷ ⓐ ⓑ www.dallmeier.com...
  • Page 23 The camera is equipped with a motor-driven P-Iris varifocal lens. The focal length (zoom) and the focus are adjusted over the network in the “WebConfig” user interface of the camera (more information can be found in the documentation on camera configuration). www.dallmeier.com...
  • Page 24 DF5(X)00HD-DN Commissioning ❸ ⓒ ⓑ ⓐ ⓘ ⓗ ⓓ ⓖ ⓔ ⓕ www.dallmeier.com...
  • Page 25 Memory card slot (microSDXC compatible) You can disable the LAN LEDs in the “WebConfig” user interface of the camera. For more information and detailed descriptions of the possible LAN LED states, read the documentation on camera configuration. Optional (ex factory only) www.dallmeier.com...
  • Page 26 DF5(X)00HD-DN Commissioning ❹ ⓐ ⓐ microSDXC card (optional) www.dallmeier.com...
  • Page 27 NOTICE Only use memory cards that have been tested and approved by Dallmeier. Inappropriate memory cards may cause malfunctions, damages as well as data loss and may result in the loss of warranty. Damage to the device or to the optional memory card...
  • Page 28 DF5(X)00HD-DN Commissioning ❺ ⓐ Earthing connection (functional earth) ⓐ www.dallmeier.com...
  • Page 29 Commissioning DF5(X)00HD-DN Recommended accessories for earthing connection: 1× Pan head screw M3 × 12 (EN ISO 7045 / DIN 7985) 1× Flat washer M3 (DIN 125 A3.2) 2× Tooth lock washer M3 (DIN 6797 A3.2) www.dallmeier.com...
  • Page 30: Pin Assignment

    Weidmüller male connector SL 3.50/02/90G (mating connector: Weidmüller BL 3.50/02/180 SN) In order to comply with UL’s requirements, always use a UL-certified, Limited Power Source (LPS) Class 2 power supply unit when operating the device with a separate power supply unit. www.dallmeier.com...
  • Page 31 Line OUT (stereo) Left channel Left channel Ring Right channel Right channel Sleeve Ground Ground Audio Line IN (stereo) Input level: max. 2.83 V Input impedance: 29 kΩ Audio Line OUT (stereo) Output level at 10 kΩ load: max. 3.11 V Output impedance: 320 Ω www.dallmeier.com...
  • Page 32 DF5(X)00HD-DN Commissioning ⓫ ⓬ ⓾ Contact I/O , RS485 interface (full duplex, half duplex) Weidmüller male connector S2L 3.50/12/90G (mating connector: Weidmüller B2L 3.50/12/180 SN) Optional (ex factory only) www.dallmeier.com...
  • Page 33 Half Duplex RS485_Y: TX+/RX+ (Non-inverting Driver Output and Non-inverting Receiver Input) RS485_Z: TX−/RX− (Inverting Driver Output and Inverting Receiver Input) Contact IN 1 – 3 For use with potential-free switch contacts Contact OUT Open-Drain output (max. 5 V DC, 500 mA switched to GND) www.dallmeier.com...
  • Page 34: Connection And Login

    Web browser Microsoft Internet Explorer 11 (Windows 7) Microsoft Edge (Windows 10) Google Chrome Mozilla Firefox (latest available version of each browser) Browser settings JavaScript enabled Ethernet 100 Mbps (or more) Sound Sound card or on-board sound chip (min. 16 bit) www.dallmeier.com...
  • Page 35: Connection

    ➡ Enter the IP address of the device into the address bar of the web browser. ➡ Confirm the input. The connection to the device is then established. After the successful connection to the device, the login dialog is displayed. www.dallmeier.com...
  • Page 36: Login

    ➡ Enter your login credentials. ➡ Confirm with “OK”. After the successful login, the graphical user interface of the configuration mode is displayed. ➡ Configure the required settings. ➡ Finally click “LOGOUT” to log out of the device. www.dallmeier.com...
  • Page 38: Technical Specifications

    1× Contact OUT Memory card slot 1× (microSDXC compatible) Power IN 1× Weidmüller male connector SL 3.50/02/90G (mating connector: Weidmüller BL 3.50/02/180 SN) Optional (ex factory only) Only use memory cards that have been tested and approved by Dallmeier. www.dallmeier.com...
  • Page 39 Approx. 560 g (1.23 lbs) Environmental Conditions Suitable installation sites Indoor Operating temperature −20 °C to +50 °C (−4 °F to 122 °F) Relative humidity 0 % – 90 % RH, non-condensing For detailed technical specifications and possible updates, see the current product data sheet (available on www.dallmeier.com). www.dallmeier.com...
  • Page 40: Dimensions

    DF5(X)00HD-DN Commissioning 12 Dimensions 71 mm (2.8") 176 mm (6.93") 63 mm (2.48") 6 mm (0.24") www.dallmeier.com...
  • Page 44 Dallmeier electronic GmbH & Co.KG Bahnhofstr. 16 · 93047 Regensburg · Germany Phone +49 941 8700-0 · Fax +49 941 8700-180 www.dallmeier.com · info@dallmeier.com...

This manual is also suitable for:

Df5200hd-dnDf5300hd-dn

Table of Contents