DDF4620HDV-DN Commissioning English 004937 / 1.0.0 / 2014-03-20...
Page 2
Redmond, Washington, USA Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the com- plete identification of third-party trademarks and indication of the respective holder of rights.
DDF4620HDV-DN-SM Commissioning 1 Validity This document applies to the following device: • DDF4620HDV-DN-SM (surface mount variant) Figures in this document may differ from the actual product. 2 Documents Data Sheet The document “Data sheet” contains detailed technical specifications and features of the device.
Commissioning DDF4620HDV-DN-SM 3 Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger: DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Page 6
DDF4620HDV-DN-SM Commissioning For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows ( ➡ ): ➡ Carry out instructions one after the other in the sequence described.
• System Components Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components may cause malfunctions, damages and data loss and may result in the loss of warranty.
Page 8
DDF4620HDV-DN-SM Commissioning • Documentation Read the documents included in the delivery carefully and thoroughly. Always observe the contained instructions, notes and warnings. The product documentation contains several documents which are included in the delivery in printed form and/or on a digital medium.
Page 9
Commissioning DDF4620HDV-DN-SM • Operating Conditions Unfavourable operating conditions may shorten the life of the device and may cause malfunctions, damages and data loss and may result in the loss of war- ranty. Observe the specifications given in the technical data, the operating condition requirements and the maintenance instructions.
Certain functions and features may require the purchase of an additional license. Transportation and Packaging Store the original packaging for later transportation. Dallmeier is not responsible for any damage resulting from unprofessional/im- proper transportation. The device should only be shipped in the original packaging.
Visit www.dallmeier.com for possible updates. Appropriate Use The DDF4620HDV-DN-SM (surface mount variant) is a hybrid HD network camera built into a vandal-resistant (IK10) dome enclosure. In addition to HD video over IP (Ethernet), the hybrid camera provides for a simul- taneous analog SD (PAL/NTSC) video output via BNC (CVBS).
Page 12
DDF4620HDV-DN-SM Commissioning NOTICE The DDF4620HDV-DN-SM is designed for indoor installations. However, an outdoor installation may be permitted, but only in compliance with the following instructions/recommendations: • Only use IP67 (Ingress Protection 67) approved components and assemblies. • Always use the delivered O-rings.
Commissioning DDF4620HDV-DN-SM 6 Requirements General Unfavourable local conditions may shorten the lifetime of the product and may cause malfunctions or damages. Do not install/operate the device in places • with a large amount of dust and dirt, • with steam or oil vapours (e.g. kitchen), •...
Page 14
DDF4620HDV-DN-SM Commissioning • Always disconnect the separate 12 V DC power supply unit from the mains socket (pull out the power plug) before connecting or disconnecting the device. • In order to comply with UL’s requirements, always use a UL-certified, Limited Power Source (LPS) Class 2 power supply unit when operating the device with a separate 12 V DC power supply unit.
Commissioning DDF4620HDV-DN-SM 7 Maintenance The device may only be opened by qualified personnel for commissioning, inspec- tion, maintenance and repair. Cleaning If it is necessary to clean the device, observe the following notes: NOTICE Damage to the surface of the device ➡...
DDF4620HDV-DN-SM Commissioning 8 Installation and Commissioning The installation and commissioning of the device may only be carried out by quali- fied personnel. WARNING Falling device/objects or collapsing ceiling Danger of death or serious injury to the head ➡ Observe the manufacturer’s instructions about the maximum adequate carrying capacity of the sup- porting structure.
Page 17
Commissioning DDF4620HDV-DN-SM NOTICE Damage to the device resulting from improper power supply The device can be powered via Power over Ethernet (PoE, Class 0, IEEE 802.3af) or supplied with a separate 12 V DC power supply unit. However, always beware not to use both power sources simultaneously.
Page 19
Commissioning DDF4620HDV-DN-SM ⓐ T20 torx screw (3×) ⓐ ➡ Loosen the torx screws of the housing. www.dallmeier.com...
Page 20
DDF4620HDV-DN-SM Commissioning ❷ ➡ Remove the housing/bubble. www.dallmeier.com...
Page 21
Commissioning DDF4620HDV-DN-SM ❸ ⓐ Threaded blanking plug ⓑ O-ring ⓐ ⓑ ➡ Remove the threaded blanking plug of the side cable entry (use a screw- driver). www.dallmeier.com...
Page 22
DDF4620HDV-DN-SM Commissioning ⓐ Alternative cable feedthrough ⓐ Always use the threaded blanking plug and O-ring to securely seal the unused cable entry (the O-ring is only required when sealing the side cable entry, see previous page). www.dallmeier.com...
Page 23
Commissioning DDF4620HDV-DN-SM ❹ ⓐ ⓑ ⓐ Gasket (adhesive-backed) ⓑ Threaded blanking plug ➡ Adhere the delivered gasket to the bottom of the housing base. www.dallmeier.com...
Page 25
Commissioning DDF4620HDV-DN-SM ⓐ Screwdriver ⓐ ➡ Mark the drill holes on the ceiling/wall (use the delivered drilling template). ➡ At the marked locations, drill holes fitting the used screws/anchors. ➡ Push anchors suitable for the ceiling/wall material into the drill holes.
Page 26
DDF4620HDV-DN-SM Commissioning ❻ ⓐ ⓑ ⓐ PG16 cable gland ⓑ O-ring ➡ Run the required cables through a PG16 cable gland. www.dallmeier.com...
Page 27
Commissioning DDF4620HDV-DN-SM ➡ Screw the PG16 cable gland in the appropriate thread of the housing base (always use the O-ring for the side cable entry). www.dallmeier.com...
Page 28
DDF4620HDV-DN-SM Commissioning ❼ ⓐ ⓖ ⓕ ⓔ ⓑ ⓒ ⓓ ➡ Connect the required cables to the connectors of the camera module. www.dallmeier.com...
Page 29
Commissioning DDF4620HDV-DN-SM ⓐ Analog video output (BNC, CVBS) ⓑ DC auto iris interface ⓒ microSDHC card slot ⓓ Audio OUT / Microphone IN (3.5 mm phone jack) ⓔ LAN / PoE (RJ45 jack, PoE conformity IEEE 802.3af) ⓕ 12 V DC Power IN (Weidmüller male connector SL 3.50/02/90G) ⓖ...
Page 33
Commissioning DDF4620HDV-DN-SM ⓐ Locking screw (focus) ⓐ Remote Back Focus Control The camera is equipped with the function “Remote Back Focus Control”. Besides a manual adjustment on the lens, the focus can also be set over the network in the “WebConfig” user interface of the camera (more information can be found in the documentation on camera configuration).
Page 34
DDF4620HDV-DN-SM Commissioning ⓫ ⓐ Black inner dome cover ⓐ ➡ Attach the housing to the housing base while ensuring that the ambient light sensor is not covered by the black inner dome cover. www.dallmeier.com...
Page 35
Commissioning DDF4620HDV-DN-SM ⓬ ➡ Tighten the 3 torx screws of the housing with a T20 torx screwdriver. www.dallmeier.com...
DDF4620HDV-DN-SM Commissioning 9 Pin Assignment Ring Sleeve Audio OUT / Microphone IN (3.5 mm phone jack, for stereo plug) Audio OUT (mono) Microphone IN (mono) Not used Signal Not used Ring Signal Sleeve Ground Ground NOTICE For a clean (interference-free) audio signal transmis- sion, the Audio IN/OUT Y-Cable Connector FGA-30 is required (optionally available).
Page 37
Commissioning DDF4620HDV-DN-SM 12 V DC (+) 12 V DC (−) 12 V DC Power IN (Weidmüller male connector SL 3.50/02/90G) DC auto iris interface Pin No. Function − Control Control Drive Drive − www.dallmeier.com...
DDF4620HDV-DN-SM Commissioning 10 Connection and Login The configuration of the device is carried out with a PC/web browser via the local area network (LAN). Alternatively, the PC can be directly connected to the device via an Ethernet crossover cable. Minimum System Requirements...
Page 39
• a more powerful PC is required if several devices are simultaneously configured with live video display (and/or live audio output). • a DirectX compatible graphics card and the Dallmeier Live Video ActiveX are not required for the configuration without live video display or live audio output.
DDF4620HDV-DN-SM Commissioning Connection The factory default IP address of the device is 192.168.2.28. ➡ Ensure that the PC/web browser can establish a connection to the device via Ethernet. ➡ Start the web browser. ➡ Enter the IP address of the device into the address bar of the web browser.
Commissioning DDF4620HDV-DN-SM Login The graphical user interface of the configuration mode is displayed for authorized users only. The factory default admin password is “3”. NOTICE Risk of misuse by unauthorized users ➡ Change the factory default admin password as soon as possible.