  • Page 1 DF5200HD-IR-ANPR Commissioning English 005748 / 1.0.5 / 2018-12-17...
  • Page 2 Mozilla and Firefox of Mozilla Foundation headquartered in Mountain View, California, USA. Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the complete identifi- cation of third-party trademarks and indication of the respective holder of rights.
  • Page 3 1× 1× 1× 1× 1× 1× 4× 4× 4× 1×...
  • Page 5: Table Of Contents

    DF5200HD-IR-ANPR Contents 1 Validity 2 Documents This Document Other Applicable Documents 3 Typographical Conventions 4 Safety Instructions 5 General Notes Scope of Delivery Transportation and Packaging Warranty Appropriate Use Approvals/Certifications 6 Requirements Ambient Conditions Power Supply 7 Maintenance 8 Installation and Commissioning 9 Front View of Camera...
  • Page 6: Validity

    Always follow the contained instructions, notes and warnings and ob- serve the technical specifications in the product data sheet. Keep all documents in legible condition and in a suitable location for future reference. Regularly check the website www.dallmeier.com for the latest updates on product documentation. www.dallmeier.com...
  • Page 7: This Document

    DF5200HD-IR-ANPR This Document Commissioning The document “Commissioning” (this document) contains detailed de- scriptions on installation, connection and commissioning of the device as well as safety instructions and general notes. The target audience of this document is trained system integrators. Other Applicable Documents Data Sheet The document “Data Sheet”...
  • Page 8: Typographical Conventions

    DF5200HD-IR-ANPR Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger:  DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.  WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 9 DF5200HD-IR-ANPR For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows (➡). ➡ Always carry out instructions one after the other in the sequence described. “Expressions” in quotation marks generally indicate a control element on the device (switches or labels) or on its user interface (buttons, menu items).
  • Page 10: Safety Instructions

    • Modifications Do not make any modifications to the hardware or software that have not been tested and approved by Dallmeier. Inappropriate modifications may cause malfunctions, damages and data loss and may result in the loss of warranty.
  • Page 11 Keep all documents in legible condition and in a suitable location for future reference. Regularly check the website www.dallmeier.com for the latest updates on product documentation. • Condensation Water If the device is brought from a cold to a warm environment, resulting condensation water may cause malfunctions and damages.
  • Page 12 DF5200HD-IR-ANPR • Operating Conditions Unfavorable operating conditions may shorten the life of the device and may cause malfunctions, damages and data loss and may result in the loss of warranty. Observe the specifications given in the technical data, the operating condition requirements and the maintenance instructions.
  • Page 13: General Notes

    DF5200HD-IR-ANPR General Notes Scope of Delivery Included in the standard scope of delivery is: • 1× Outdoor wall mount bracket with internal cable routing • 1× Flat gasket (adhesive-backed) for outdoor wall mount bracket • 1× Drilling template for outdoor wall mount bracket •...
  • Page 14: Transportation And Packaging

    The terms and conditions valid at time the contract was signed shall apply. Appropriate Use The DF5200HD-IR-ANPR is a special camera with integrated IR illumina- tion. The images provided by the camera are optimized for the automatic recognition of vehicle number plates on a SEDOR® ANPR Server appli- ance.
  • Page 15 DF5200HD-IR-ANPR The outstanding infrared sensitivity of the camera is supported by the in- tegrated homogeneous IR illumination. It is based on semi-covert 850 nm high power LEDs and permits an illumination range of up to 18 m. The camera is equipped with special presets in order to provide optimum recordings for the number plate recognition with SEDOR®...
  • Page 16: Approvals/Certifications

    • RCM • UL • DIN 50130-4 compliant Visit www.dallmeier.com for possible updates. Note (USA) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer- ence when the equipment is operated in a commercial environment.
  • Page 17: Requirements

    DF5200HD-IR-ANPR Requirements Ambient Conditions Unfavorable local conditions may shorten the lifetime of the product and may cause malfunctions or damages. ➡ Do not install/operate the device in places • with a large amount of dust and dirt, • with steam or oil vapors (e.g. kitchen), •...
  • Page 18: Power Supply

    DF5200HD-IR-ANPR Power Supply The camera is operated via Power over Ethernet (PoE, Class 0) and is com- patible with all IEEE 802.3af compliant Power Sourcing Equipment (PSE).  WARNING Personal injury from electrical shock as well as property damage caused by lightning strikes, over-voltages (electrical surges) and electromagnetic interferences Danger of death or serious injury as well as damage to the device and malfunctions ➡...
  • Page 19: Maintenance

    DF5200HD-IR-ANPR Maintenance The device may only be opened by qualified personnel for commission- ing, inspection, maintenance and repair. Cleaning If it is necessary to clean the device, observe the following notes: NOTICE Damage to the surface of the device ➡ Clean the housing (outside) with a soft, dry and antistatic cloth.
  • Page 20: Installation And Commissioning

    DF5200HD-IR-ANPR 8 Installation and Commissioning The installation and commissioning of the device may only be carried out by qualified personnel.  WARNING Falling device/objects Danger of death or serious injury ➡ Observe the manufacturer’s instructions about the maximum adequate carrying capacity of the supporting structure.
  • Page 21 DF5200HD-IR-ANPR ❶ Fig. 1 ➡ Remove the paper backing from the self-adhesive gasket. ➡ Adhere the gasket to the back of the outdoor wall mount bracket while ensuring that the gasket is aligned as illustrated in Fig. 1. www.dallmeier.com...
  • Page 22 DF5200HD-IR-ANPR ❷ Fig. 2 ➡ Attach the Anti-IR reflection hood (black) to the sunshield as illus- trated in Fig. 2 and Fig. 3. www.dallmeier.com...
  • Page 23 DF5200HD-IR-ANPR Fig. 3 The Anti-IR reflection hood helps to prevent unwanted reflections from the built-in IR-LEDs. Without the use of the Anti-IR reflection hood some IR stray light could be reflected back from the inside finish of the sunshield which could reduce the overall image quality.
  • Page 24 DF5200HD-IR-ANPR ❸ Fig. 4 Pre-assembled Cat.5e S/UTP patch cable terminated with RJ45 (8P8C) modular plug (male connector) Hexagon socket head cap screw (fully threaded, DIN 912 / ISO 4762, M8 × 12, for hex key size: 6 mm) Hex key (size: 6 mm) www.dallmeier.com...
  • Page 25 DF5200HD-IR-ANPR Fig. 5 ➡ Run the pre-assembled RJ45 patch cable through the outdoor wall mount bracket. ➡ Assemble the camera housing to the outdoor wall mount bracket as illustrated in Fig. 4 and Fig. 5. ➡ Tighten the hexagon socket head cap screw with the hex key www.dallmeier.com...
  • Page 26 DF5200HD-IR-ANPR ❹ ➡ Connect the pre-assembled RJ45 patch cable of the camera (Fig. 5 - ) to an IEEE 802.3af compliant PoE switch or PoE injector (midspan device) in your network. There are different ways to connect the camera to your network: •...
  • Page 27 DF5200HD-IR-ANPR Fig. 8 NOTICE Damage to RJ45 plugs/jacks caused by moisture, dust and dirt If using the delivered “Cat.5e RJ45 inline coupler STP” (Fig. 6 and Fig. 8) or the “E-DAT modul Cat.6 8(8) jack, T568A” (Fig. 7), you have to wrap the cable/connector transitions with a self-amalgamating tape to avoid damage to the RJ45 plugs/jacks caused by moisture, dust and dirt.
  • Page 28 DF5200HD-IR-ANPR ❺ Fig. 9 4× Chipboard screw Ø 5 × 40 mm (partly threaded, pan head, 6-lobe drive/Torx, T25) 4× Plain washer (VA, DIN 9021 / ISO 7093, inner diameter: 5.3 mm) 4× Expansion nylon plug S6 (drill hole diameter: 6 mm, min. drill hole depth: 40 mm, anchor length: 30 mm)
  • Page 29 DF5200HD-IR-ANPR NOTICE Damage to the device due to water penetration or other environ- mental influences ➡ Check whether the delivered gasket is properly adhered to the outdoor wall mount bracket (as illustrated in Fig. 1). ➡ Protect the device from direct influence of weather conditions (rainfall, direct sunlight etc.). • Always use a protected installation site for outdoor installations (e.g.
  • Page 30 DF5200HD-IR-ANPR ❻ ➡ Connect your PoE switch or PoE injector (midspan device) to the mains socket and switch it on. ➡ Establish an Ethernet connection to the camera with a web browser (see chapter “Connection and Login” on page 34).
  • Page 31 DF5200HD-IR-ANPR Fig. 12 Detailed descriptions of the camera configuration can be found in separate documentations that are available on www.dallmeier.com. www.dallmeier.com...
  • Page 32: Front View Of Camera

    DF5200HD-IR-ANPR Front View of Camera Fig. 13 Motor-driven P-Iris megapixel varifocal lens Semi-covert 850 nm high-power LEDs for homogeneous IR illumination Ambient light sensor Integrated microphone www.dallmeier.com...
  • Page 33: Wire Color Code For Pre-Assembled Patch Cable

    DF5200HD-IR-ANPR 10 Wire Color Code for Pre-assembled Patch Cable Fig. 14 Pre-assembled Cat.5e S/UTP patch cable terminated with RJ45 (8P8C) modular plug (male connector) Pin No. Pair Color Orange Black Blue White Green Yellow Brown www.dallmeier.com...
  • Page 34: Connection And Login

    DF5200HD-IR-ANPR 11 Connection and Login The configuration of the device is carried out with a PC and web browser over the local area network (LAN). Alternatively, the client PC can be directly connected to the device via an Ethernet crossover cable (PoE injector required).
  • Page 35: Connection

    DF5200HD-IR-ANPR Connection The factory default IP address of the device is: 192.168.2.28 ➡ Ensure that your PC/web browser can establish a connection to the device via the Ethernet (if necessary, contact your network administra- tor for more information and assistance).
  • Page 36: Login

    ➡ Configure all required settings (such as the ideal focus position). ➡ Finally, click “LOGOUT” to log out of the device. Detailed descriptions of the camera configuration can be found in separate documentations that are available on www.dallmeier.com. www.dallmeier.com...
  • Page 37 DF5200HD-IR-ANPR www.dallmeier.com...
  • Page 38: Technical Specifications

    DF5200HD-IR-ANPR 12 Technical Specifications Connections/Interfaces Power & Ethernet 1× Pre-assembled Cat.5e S/UTP patch cable terminated with RJ45 (8P8C) modular plug (male connector): • 10BASE-T • 100BASE-TX • 1000BASE-T • PoE (IEEE 802.3af) IR Illumination Type Semi-covert 850 nm high power LEDs Range Up to approx.
  • Page 39 DF5200HD-IR-ANPR Mechanical Data Adjustment 2-axis (pan/tilt) Color White IP rating IP66 Dimensions See chapter “Dimensions” on page 42. Weight Approx. 2 kg (4.41 Ibs) Environmental Conditions Suitable Indoor and outdoor installation sites Operating −40 °C to +50 °C (−40 °F to 122 °F), temperature minimum start-up temperature: −30 °C (−22 °F) Relative humidity 0% – 90% RH, non-condensing...
  • Page 40: Presets And Mounting

    DF5200HD-IR-ANPR 13 Presets and Mounting Observe the relation between exposure preset/variant and installation heights/distances for the operation of the camera with SEDOR® ANPR Server. Preset for Camera Minimum Capture width Maximum Capture width variant 401 installation distance at minD distance at maxD (3 – 8 m)
  • Page 41 DF5200HD-IR-ANPR minD maxD maxW minW Observe the permissible angles for the positioning of the camera relative to the vehicle/number plate. Position Vertical angle Max. 30° Horizontal angle Max. 30° Lateral tilt Max. 15° Use the preview of the configuration interface for controlling. The position of the number plate on the screen must correspond to the above requirements.
  • Page 42: Dimensions

    DF5200HD-IR-ANPR 14 Dimensions 362 mm (14.25") 229 mm (9.02") 233 mm (9.17") 99 mm (3.90") 71 mm (2.80") www.dallmeier.com...
  • Page 44 Dallmeier electronic GmbH & Co.KG Bahnhofstr. 16 · 93047 Regensburg · Germany Phone +49 (0) 941 87 00-0 · Fax +49 (0) 941 87 00-180 www.dallmeier.com · info@dallmeier.com...

Table of Contents