Common error codes for the "Extended" instructions

Table 8- 143 Common condition codes for the extended instructions
Condition code (W#16#....)
8022
8023
8024
8025
8028
8029
8030
803A
If one of these errors occurs when a code block is executed the the CPU goes to STOP mode, unless you use the
1
GetError or GetErrorID instructions within that code block and create a programmed reaction to the error.
S7-1200 Programmable controller
System Manual, 11/2011, A5E02486680-05
Description
1
Area too small for input
Area too small for output
Illegal input area
Illegal output area
Illegal input bit assignment
Illegal output bit assignment
Output area is a read-only DB.
DB does not exist.