Air Exhaust Ventilation; Fluid Supply Line - Graco Husky 2200 Operation

Air-operated diaphragm pump
Hide thumbs Also See for Husky 2200:
Table of Contents

Advertisement

Air Exhaust
Exhaust Ventilation
Ventilation
Air
Air
Exhaust
Ventilation
If pumping toxic fluids, you must vent the exhaust
away from people, animals, food handling areas,
and all sources of ignition. Follow all applicable
codes.
NOTICE
NOTICE
NOTICE
The air exhaust port is 1 in. npt(f). Do not restrict
the air exhaust port. Excessive exhaust restriction
can cause erratic pump operation.
A
Air supply line
B
Bleed-type master air valve (may be
required for your pump installation)
C
Air filter/regulator assembly
D
Master air valve (for accessories)
J
Air inlet port (not visible)
Fluid
Fluid
Fluid Supply
Supply Line
Supply
Line
Line
1. Use grounded, flexible fluid hoses (E). See
Ground The System, page
3A2578E
K
S
T
U
10.
www.northridgepumps.com
To
To provide
To
provide
provide a a a remote
remote
remote exhaust:
exhaust:
exhaust:
1. Remove the muffler (U) from the pump air
exhaust port (K).
2. Install a grounded air exhaust hose (S) and
connect the muffler to the other end of the hose.
The minimum size for the air exhaust hose is 1
in. (26 mm) ID. If a hose longer than 15 ft (4.57
m) is required, use a larger diameter hose. Avoid
sharp bends or kinks in the hose.
3. Place a container (T) at the end of the air exhaust
line to catch fluid in case a diaphragm ruptures.
If the diaphragm ruptures, the fluid being pumped
will exhaust with the air.
Air exhaust port
Grounded air exhaust hose
Container for remote air exhaust
Muffler
Installation
11

Advertisement

Table of Contents
loading