Configuration - NEC Express5800 SIGMABLABE User Manual

10gb intelligent l3 switch
Hide thumbs Also See for Express5800 SIGMABLABE:
Table of Contents

Advertisement

Configuration

The Switch Module can be configured locally using the Serial Port or remotely using the Ethernet ports.
Connection via Serial Port
Serial interface is connected between this switch module and the EM card. Therefore It is available to connect from
the Enclosure Manager by using "CONNECT SWITCH" command on Blade Enclosure(10U) or "connectswitch"
command on Blade Enclosure(6U).
Connection via Network
To connect to this Switch Module via network, you need to assign an IP address to it. You can access the
browser-based interface or the command line interface in the switch through a telnet application or Web browser
by using the assigned IP address.
IP address is configured by the following.
- Assignment by DHCP (by default)
- Manual assignment
- Assignment by DHCP
By default, the management network interface on the Switch Module is set up to obtain its IP address from the
DHCP server on the Enclosure Manager Card. You can configure the IP address in the EM Card. For more
information, see the EM Card User's Guide.
NOTES:
- Manual assignment
You can assign the IP address by connecting to the Switch Module via the local console. Refer to the following
examples, you can configure them.
BLADE OS CLI
>> # /cfg/sys/dhcp disable
>> # /cfg/l3/if 256
>> IP Interface 256# addr 205.21.17.3
Current IP address:
New pending IP address: 205.21.17.3
Pending new subnet mask: 255.255.255.0
. . . . . . . . . . . .
>> IP Interface 256# ena
>> IP Interface 256# ../gw 4
>> Default gateway 4# addr 205.21.17.1
>> Default gateway 4# ena
>> Default gateway 4# apply
>> Default gateway 4# save
If the IP address cannot be obtained from the DHCP server, access
the local console of the Switch Module and assign the IP address
manually. Refer to "Manual assignment" below. After assigning the IP
address, then access the Switch Module via network.
Port 37 of the Switch Module is connected with the management
network in the Blade Enclosure.
Refer to the Blade Enclosure User's Guide and the EM Card User's
Guide about how to connect or configure the Enclosure Management
LAN port.
If the http button on EM card is disappeared, please Enter IP address
directly on web browser.
0.0.0.0
(Disable dhcp)
(Select IP interface 256)
(Assign IP address for the Interface)
(Enable IP interface 256)
(Select default gateway 4)
(Assign IP address for a router)
(Enable default gateway 4)
(Apply the configuration)
(Save the configuration)