CLEANING, MAINTENANCE AND STORAGE

Cleaning, maintenance and storage of a respirator with a PASS device is part of the
normal respirator CLEANING AND STORAGE and REGULAR OPERATIONAL IN-
SPECTION as described in the OPERATING AND MAINTENANCE INSTRUCTIONS
supplied with each 3M Scott Air-Pak X3 Pro SCBA.
Refer to the PAK-TRACKER User Instructions, 3M Scott P/N 595278-01, provided
with the HHR for complete details of cleaning and storage of the HHR.
Store the respirator in accordance with the OPERATION AND MAINTENANCE IN-
STRUCTIONS provided with the respirator. Do not store respirators equipped with
PASS devices in the proximity of radio antennas or radio transmitter base units. Respi-
rators equipped with PASS devices must be stored or transported at least two (2) feet
away from radio antennas on fire equipment. Refer to the DETECTING AND AVOIDING
RADIO FREQUENCY INTERFERENCE section of this instruction for details.
Clean the exterior of the SEMS II Pro Control Console while cleaning the exterior of
the respirator by wiping with a damp sponge and thoroughly wiping dry. The Signal
Light lens on the front of the Control Console should be cleaned after every use to
insure maximum light intensity at all times. Do not use solvents for cleaning or attempt
to paint or apply decals to the exterior surfaces of the SEMS II Pro Control Console.
If during use, the respirator and/or SEMS II Pro Control Console is suspected of
being contaminated by a hazardous substance, the contaminant must be identified
and properly removed or the contaminated component(s) must be replaced before next
use. Dispose of the contaminant or the contaminated component(s) in accordance
with applicable regulatory requirements.
Except for the replacement of batteries, no attempt shall be made to do maintenance
or to make adjustments or repairs beyond the scope of this instruction manual without
proper training.

MARKING AND PAINTING

Do not mark, etch, paint, drill, or apply labels to any of the SEMS II Pro system com-
ponents or housings in any way.

REPLACEMENT PARTS AND SERVICE

The PASS device is covered by a one year warranty.
Consult your authorized 3M Scott representative, distributor or service center as to
the availability of service and parts for the PASS device. Replacement batteries of the
type designated are commercially available over the counter, from your authorized
distributor, and from most industrial battery distributors.
Except for the replacement of batteries, do not attempt to do maintenance or
to make adjustments or repairs beyond the scope of this instruction manual
without proper training.

RETIREMENT CRITERIA AND CONSIDERATION

Retirement criteria and consideration shall be determined by 3M Scott trained and
Certified Overhaul Technicians.
P/N 595369-01 Rev B 07/19