2) After positioning the Pressure Belt Displacement Control Motor Unit, fasten it with a New Screw.
IMPORTANT!
When attaching the Pressure Belt Displacement Control Motor Unit to the Pressure Belt Unit,
always use a New Screw. The Screw used to attach the Pressure Belt Displacement Control
Motor Unit should not be reused once it is removed!

Clearing the Fixing Belt Unit Counter

If the Fixing Belt Unit Counter is not cleared after component replacement, or if the Fixing Belt Unit is not
mounted properly, some potential issues that could arise are E007-0001, 0011 and 0021.
After replacement of the Fixing Belt Unit, performance of the Operation Check from Service Mode can
suppress failures due to inadequate mounting, etc. Navigate to Service Mode: FUNCTION > FIXING > FIX-
UHP and execute the operation check.
NOTE:
• Use care not to damage the Fixing Belt during mounting.
• After replacement of the Fixing Belt Unit, apply Grease (SE1107; FY9-6036-000)
respectively to the four (4) Gears [1] on the Pressure Belt Unit and the Gear [2] of the
Fixing Drive Assembly.
Amount of Grease to apply: about in an amount of five (5) grains of rice per Gear