Setting up the Flight II for the first time.
After you have completed the physical installation of the Flight II, you need to setup the following
items before you can proceed with flight testing:
a) Select your mode of operation:
We recommend to select automatic flight detection. For this to work correctly, you will need
functioning airspeed indication and engine RPM display. Do not forget to set the take-off RPM
limit in the "Setup Limits" menu.
b) Select your units of measure
This to you in the "Setup Units" menu.
c) Set your alarm limits
This you do in the "Setup Limits" menu.
d) Set your rev counter pulses per RPM setting in the "calibration menu".
e) Select your fuel tank size in the calibration menu.
f) In the operations setup menu, select if you are using a fuel flow sender, fuel level sender or
both.
g) If you are using a fuel level sender, you need to calibrate it in the "calibration menu".
h) Zero the ASI and VSI in the calibration menu.
The above items will result in a functional installation, of course you will likely experiment with
some settings as you get to know your instrument and refine your installation.