2. Maximum floor temperature setting
Maximum floor temperature is preset at the factory
to 35°C for cable temperature safety.
Local building regulations must be observed when
changing the maximum preset temperature.
You can/must set the maximum floor temperature
on the Devireg™ 532 by taking off the front cover and
with a screwdriver adjust the sunken temperature dial
in the top left hand corner between 20° to 50°C.
4
For wooden floor constructions DEVI™ recommend
the temperature is limited to a maximum
of 30°C.
Maximum temperature setting for different floor
constructions:
Tiles on chipboard
30°C
Carpet/vinyl on chipboard
35°C
Wooden floors (parquet, plank, etc.)
30°C
Other (concrete, screed, etc.)
45°C

3. Light indications (LED)

The Devireg™ 530 series has a LED indicator above
the 2 pole safety switch (see illustration).
The LED has four indications:
• No light means the system is off.
• Red light means system is heating.
• Green light means system is standing by.
• Flashing green light means there is a problem
with the floor sensor (only applicable for 530
and 532). Please refer to section about "Trouble
shooting" for further information.
The is used for setting the thermostat in frost protec-
tion mode, i.e. keeping the room/floor temperature
(depending on type of thermostat) at 5°C at any time.