Operating Recommendations - Chore-Time FLEX-AUGER 108 Installation Instruction

Feed delivery system
Hide thumbs Also See for FLEX-AUGER 108:
Table of Contents

Advertisement

Operating Recommendations

Operating Recommendations
1.During initial start-up, the boot slide should be only partially open to prevent the full length of auger from
being charged with feed. After that, the boot slide must be fully open for delivery system operation.
2.Do not permit the FLEX-AUGER system to operate empty. Use a time clock or Auger Timer with the system
whenever possible. This reduces short cycling by operating on a preset schedule instead of on demand. It
also prevents excessive running of the system if the bin becomes empty. If the optional boot switch is used,
the fill system will shut down when the bin becomes empty.
3.Program the time clock to fill feeders often so the FLEX-AUGER System does not have to run a long period
of time to get feeders filled. Poultry feeders supplied by the FLEX-AUGER System should be operated by a
time clock so feeders start at the same time. This gives the FLEX-AUGER System a better chance to keep up
with them.
Note: The hopper level control must be positioned low in the last feeder hopper.
4.The red light on the control unit will light if feed has packed inside. If this happens, remove feed from the
drop tube and tap the side of the power unit to clear the safety switch. Keep the hopper level control in
adjustment and positioned straight up and down so the paddle swings freely. The safety switch does not take
the place of the hopper level control.
5.If the FLEX-AUGER System must be used to convey high-moisture feed, empty the auger line completely
after each running to prevent the feed from setting up in the tubes.
6.The Restrictor in the boot regulates the amount of feed flowing into the auger. Start a new system with the
Restrictor installed as shipped--full length and flush with the front of the boot. Allow the system to polish out
before adjusting the feed flow. Maximum restriction for the boots results when the restrictor is in this
position. If more feed flow is desirable, the restrictor may be shortened. Refer to the section "Restrictor
Adjustment" on Page 29.
7.When operating the Straight-Through Tandem System, open the slide on only one bin at a time!
8.Model 108 High-Moisture Corn Appplications only:
Chore-Time recommends purging the system after the last feeding each day. Do not allow feed to set in the
tubes for more than 24 hours.
Additionally, do not allow the charged system to set idle in freezing conditions for extended periods of time.
34
FLEX-AUGER® Feed Delivery System
MA1032F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLEX-AUGER 108 and is the answer not in the manual?

Questions and answers