Calibrate Water Dosing System WDS

Cold water
Warm water
Function check
7.3

Error Message

displays a list of error messages that have occurred.

7.3.1 Finding errors, error diagnosis and repair

Write down the error message and conditions. This information is important for ELRO After Sales Service.
If the steam valve blows off steam continuously during a pressure cooking process or if the maximum
temperature is not reached, this could indicate a faulty setting of the boiling point at the appliance location. If
the boiling point setting on the appliance (i.e. the maximum temperature setting) at the location does not
correspond with the actual boiling point, it must be corrected according to the installation instructions (chapter
"Setting the appliance to the height above sea level").
X101923E
*)
The quantity of water must be calibrated on site during
installation!
Fill 10 litres of water into the measuring container
press  Cold water is calibrated.
Repeat if necessary.
Fill 10 litres of water into the measuring container
press  Warm water is calibrated.
Repeat if necessary.
Return to the main menu WDS
Set 10 litres. Check both cold and hot water!
*)
Start WDS
Check the water volume flowing into the measuring
container. Calibration is correct if the water volume is 10
litres +/- 0.2.