Elro Multifunction Valve; Cleaning - ELRO 2300 Series Operating Instructions Manual

Table of Contents

Advertisement

4.5

ELRO multifunction valve

2
under pressure
valve closed
turn 180°

4.5.1 Cleaning

After each use
Weekly
4.5.2 Cleaning
X101923E
1 Valve upper body
2 Signal pin I or II
3 Deflector plate
4 Appliance lid
5 Coupling ring
6 Handle
aeration
5
valve open
Deflector plate (3) must be correctly mounted during operation!
If you place food in boiling or vacuum bags, please arrange them so they do
not clog the deflector plate (3).
The correct signal pin (2) must be inserted!
Signal pin I for: DGN, DGNS, DBGN-EDS, DBGNS-EDS, DBGNI-EDS
Signal pin II for: DBGN-ED and DBKGN-ED
The ELRO multifunction valve becomes hot during operation. Use the
foreseen handle.
The ELRO multifunction valve can be activated automatically or manually
during operation. In both cases hot steam escapes from the steam outlet
opening! Never place hands or head in front of or over this opening when
the appliance is in operation.
Valve upper body (1)
X
Procedure:
Valve is open, open appliance lid (4).
Pull off the deflector plate (3), take out the signal pin (2).
Close the appliance lid (4) and screw off the coupling ring (5), remove the
valve upper body (1).
Clean the valve upper body (1), deflector plate (3), signal pin (2) under
running water.
Assemble the ELRO multifunction valve in the reverse order.
Regularly check the proper functioning of the ELRO multifunction valve and
if parts have been damaged. If this is the case, do not put the appliance under
pressure and contact ELRO After Sales Service.
I
II
6
Signal pin (2)
X
4
3
1
2
3
Deflector plate (3)
X
19

Hide quick links: