LPI
returns a list of programmable items as follows (see explanation below):
INP1 = B | RTP1 = 6 | RTN1 = 6 | TTP1 = 90
FBI1 = 90 | RFT1 = 30 | LFE1 = 0
INP2 = B | RTP2 = 6 | RTN2 = 6 | TTP2 = 90
FBI2 = 90 | RFT2 = 30 | LFE2 = 0
OK
Entry of programmable items as follows:
Note all entries must be two or three digit numeric within the limits shown above (enter 7 as 07).
'x' is the target heatsink module number (1 or 2, or 'A' to set all available modules at once).
INPx=*
RTPx=**
RTNx=**
TTPx=**
FBIx=***
RFTx=***
LFEx=**

Factory Commands available only with a password

Typing in %(+PASSWORD) returns the following menu and allows access to protected functions.
Enter 1 to change factory data
Enter 2 to change password.
Enter 3 to set model number.
Enter 4 to reset fault count.
'1' Allows entry of up to a 16 printable character factory data string.
'2' Allows entry of up to a 16 printable character password.
'3' Allows entry of model type (see model chart below).
'4' Will clear the fault counter to 0.
There are 2 hidden commands that are not meant for field use.
'&' Will reset the running total time counter to zero (rolls back the odometer)
'!' Will do a total factory reset to default model (CAM400), password to default,
fault counter to 0, running total time counter to 0, and blank the factory data.

MODEL CHART

x
1
2
3
4
5
CA(P)2100 AMP Service Manual v1.4 inc voltage change info .doc
Input Configuration (1 character B = Balanced S = Single Ended)
Rail Positive Current Trip point in AMPS (2 digit, Limits 05 to 75)
Rail Negative Current Trip point in AMPS (2 digit, Limits 05 to 75)
Temperature Trip point in degrees Celsius (2 digit, Limits 25 to 99)
FAST Blow current setting (3 digit, Limits 090 to 190)
Rail Fault Timer hold-off in milliseconds (3 digit, Limits 10 to 255)
DC-protection tripping delay (each unit equals 5ms, Limits 0 to 99)
Model
CAM400
CA2200
CA3200
CA5200
CA2100
Configuration
2 HS 1 LED (default)
2 HS 2 LED
3 HS 3 LED
5 HS 5 LED
2 HS 2 LED