This will be available in CAP/CP v1.0.8 (released tonight or tomorrow morning). Please let me know if it sounds
good and looks like what you guys wanted and expected. Thanks !
SDA: (CAP-2100 only)
> SDA
Heatsink 1: POS 00 A | NEG 01 A | TEMP 33 °C
Heatsink 2: POS 00 A | NEG 01 A | TEMP 32 °C
SDP: (CAP-2100 and CP-500)
> SDP
Line V = 100 V
Current = 0.0 A
Temperature = 30 °C
Ground is OK.
Line Phase is OK.
LPI: (CAP-2100 only)
> LPI
INP1 = . | RTP1 =
FBI1 =
INP2 = . | RTP2 =
FBI2 =
SPI: (CAP-2100 only)
> SPI RTP1 11
> SPI RTP2 12
> SPI RTN1 13
> SPI RTN2 14
> SPI RFT1 31
> SPI RFT2 32
> SPI TTP1 92
> SPI TTP2 94
> SPI FBI1 91
> SPI FBI2 92
> SPI LFE1 1
> SPI LFE2 2
The one thing I noticed about SPI XXX# is that it seems to set the parameter only if # is "1" and then sets the
same value for both heatsinks. I'll check that out with Richard.
SFL --or-- STAT FTIME: (CAP-2100 only)
> SFL
#003: TT 0:04:44 | OT 0:00:00 | Heatsink 2: Temperature limit exceeded
#002: TT 0:04:44 | OT 0:00:00 | Heatsink 2: Temperature limit exceeded
#001: TT 0:00:00 | OT 0:00:00 | Heatsink 1: Current limit exceeded
There are 3 faults recorded.
CA(P)2100 AMP Service Manual v1.4 inc voltage change info .doc
10 | RTN1 =
10 | TTP1 =
90 | RFT1 =
30 | LFE1 =
10 | RTN2 =
10 | TTP2 =
90 | RFT2 =
30 | LFE2 =
45
0
45
0
Page 42 of 50