Ca2100 Can-Bus Function Test; Cap2100 Can-Bus Function Test - Classe Audio Delta Series Service Manual

Integrated
Table of Contents

Advertisement

Internal Temp. = 30 C
Ground is ok
Line phase is wrong
OK
After the test plug back the normal AC cable.
For a CAP2100
For this test, you will need a reverse phase AC cable and a ground missing AC cable. First of all, disconnect
the RS-232 cable from your unit. Plug the reverse phase AC cable to your unit with a 120Vac line (do this test
only at 120Vac because if you are a 240Vac your step up transformer will always say "ground missing"). Turn
on the unit. From the CAP2100 front panel: Press MENU
should see: "Inverted phase".
Now repat the test but with the Ground missing Ac cable. You should see at the AC Ground: "Ground
Missing" and the line phase should be not defined.

CA2100 CAN-BUS function test

Connecting a CAN-BUS cable from the amplifier's CAN BUS IN connector to the parallel-port adapter.
Connect the adapter to your computer with a normal parallel cable and power it up. Run file "CAN BUS
Monitor" on your computer. Locate the Universal Page window and press the "send" button. The amplifier
should respond by powering up. As soon as the power-up is complete the amp will begin sending messages
on the CAN bus (which you will see in the Output window). A new message should appear every second.
Press the "send" button again to power-down the amp. Repeat this test using the CAN BUS OUT connector
on the amplifier (nothing else needs to be changed). See Technical Manual for more details.

CAP2100 CAN-BUS function test

Connecting a CAN-BUS cable from the amplifier's CAN BUS IN connector to the parallel-port adapter.
Connect the adapter to your computer with a normal parallel cable and power it up. Run file "CAN BUS
Monitor" on your computer. As soon as the power-up is complete the amp will begin sending messages on
the CAN bus (which you will see in the Output window). A new message should appear every three seconds.
Repeat with the CAN BUS OUT connector on the amplifier (nothing else needs to be changed).
Dielectric strength test
Step 1
1. Hook up DUT Adapter as per Figure 1.
2. Plug the 02100A-13 cable with the attached IR cable to IR IN of the EUT (equipment under test) and the other
end to the RETURN receptacle of the HYPOT III.
3. Plug in an AC power cord (3-Prong Plug) to the Device Under Test Adapter (DUT) and EUT,
4. Make sure the display of the HYPOT III shows M0-1. If not push MENU and then MEMORY to step to the
correct location.
5. Push "exit" then "TEST".
6. Press TEST on the HYPOT III.
CA(P)2100 AMP Service Manual v1.4 inc voltage change info .doc
STATUS
SENSOR. At the AC line phase you
Page 33 of 50