Button function test

Verify that all the front panel buttons work well. See section on Input Selection and AMP# selection.
Verify that the Input type (Bal or S/E) and AMP# (1-15) are reflected in the RS-232 communication.

Trigger function test

For a CA2100
For this test you will need another CA(M)-XX00. Connect a switched +5Vdc signal (Trigger/IR box) to the
trigger-in input on the Trigger/IR board and from the trigger-out input connect a
cable to the trigger-in input
of another unit. If the 2 amps were on Standby it should respond by powering up. If the 2 amps was already
ON, the trigger will be ignored. When you switch the trigger signal off, the both amps will power-down (back
to Standby). The trigger-out signal is just a copy of the trigger-in signal, it should measures about 0.2 volts
lower.
IR
Trigger
IR
Trigger
IR
TR
in out
in out
in out
in out
Trigger/IR box
unit #1
unit #2
For CAP2100
Turn the CAP2100 on. Connect the Trigger out from the IR/Trigger box to the Trigger in from the unit.
Connect a 1/8 cable to your Trigger out of the unit. Put you multimeter to the other end of the of the 1/8
cable, you should see 0Vdc (relative to the output ground or the ground of the 1/8 cable) if your unit is OFF.
Turn on the IR/Trigger box. You should see on your meter about 10Vdc and see the unit turn ON. By
switching OFF the IR/Trigger box, the unit should turn OFF and your voltage should drop to 0Vdc. Repeat 2-3
times.

IR function test

For a CA2100
For this test you will need another CA(M)-XX00 and a Delta Classé remote control. Connect a cable from the
IR out from the trigger/IR box to the IR-in input of the unit and then, from the IR-out input connect another
cable to the IR-in input of another unit. Target the remote control to the IR/TRIGGER box IR eye and test some
IR functions (Power toggle, DIM, MUTE). Both of the unit should perform the asked IR function.
IR
Trigger
IR
Trigger
IR
TR
in out
in out
in out
in out
Trigger/Ir box
unit #1
unit #2
CA(P)2100 AMP Service Manual v1.4 inc voltage change info .doc