36 | FIRMWARE UPDATE | GEOKON
13. A progress bar will appear. The update process will normally take one to
two minutes.
14. Once the update has finished, operation will return to normal.
FIGURE 41: Update Finished
15. Repeat the above process with all the nodes in the network.
The firmware update is now complete.
E.2 FIRMWARE TROUBLESHOOTING
□
Perform updates using the
adapter. Other adapters and native serial ports have been unreliable.
□
Make sure the batteries are fresh.
E.3 CHANGE SUMMARY FOR FIRMWARE VERSIONS
Version
(Most recent at top)
■ Revised bootstrap loader (BSL) provides firmware updates via external USB. Internal "CHANNEL"
DIP switches don't need to be changed when using new software utility to upload new firmware
images.
■ Make USB the default port.
(788) 200410
■ Automatically configure and use Digi International 900SX and 868SX radios.
■ Nodes fill device table to provide information for AgentMobile handheld interaction.
■ Initialize GPIO to minimize S-8800-2 sleep current.
■ Recognize models 6150F, 6150G, etc., as MEMS.
■ Corrected Leap Day bug that prevented nodes from relaying data to sensemetrics THREADs
(787) 200311
after joining.
■ Prevent concurrent flash writes or erasures to protect flash integrity.
■ Verify newly-written flash metadata matches RAM client. Rewrite metadata if difference
detected.
(786) 191023
■ Load prior record into RAM during boot if newer metadata in flash is corrupted.
■ Stop sampling supervisor every minute.
■ Update supervisor signal strength regularly.
■ Sets GeoNet to "airplane mode", silencing radio for logger-only operation.
(784) 190807
■ Corrected fault that prevented sensemetrics threads from reading MUX boards.
(783) 190502
■ Fixes intermittent addressable discovery of drop 1.
(782) 190311
■ USB lock up corrected.
■ Log data from Addressable Temperature Sensors (3810A) and Addressable Vibrating Wire
Readers (8020-30).
■ Simplified keypad operation.
(779) 190125
■ Corrected defects that impeded prompt radio network connections.
■ Augmented power control and battery monitoring.
■ Single-Channel Node: VW is never disabled.
■ MUX: VW channel disabled after 10 failed reads.
181025 through 180228
■ MEMS: MEMS drops disabled after 10 failed reads.
■ Single-Channel Node: VW is never disabled.
180213 through 170818
■ MUX: VW channel disabled after 10 failed reads.
■ Single-Channel Node: VW is disabled after 5 failed reads.
Prior to 170818
■ MUX: VW is disabled after 5 failed reads.
TABLE 19: Change Summary