Making 10-Pin Cable Connections; Notes Concerning Multi-Channel And Addressable Nodes; Figure 18: Terminal Connections; Table 7: Node Wiring - Geokon GeoNet 8900 Series Instruction Manual

Wireless data hosting system
Hide thumbs Also See for GeoNet 8900 Series:
Table of Contents

Advertisement

4.
Pull gently on each conductor to ensure it is secure.
5.
Tighten the cable gland nut until it firmly grips the outer jacket of the cable.
The cable gland nut must be properly tightened to prevent water entry. Do
not over-tighten, as this might strip the plastic threads.
6.
Pull gently on the gauge cable to ensure it is held in place by the cable gland.
7.
Repeat these steps for each gauge cable you need to connect.
RS-485 (ADR)

FIGURE 18: Terminal Connections

To prevent a short circuit, do not allow bare leads to touch each other during or
after wiring.
RS-485 (Addressable Node)
Position
Color
Description
485+
WHITE
RS-485 Data +
485−
GREEN
RS-485 Data −
12V
RED
12 Volt Bus
GND
BLACK
Bus Ground
SHD
BARE
Analog Ground (shield)
TABLE 6: Node Wiring

3.5.2 MAKING 10-PIN CABLE CONNECTIONS

To connect a device using a 10-pin connection:
1.
Remove the cover from the 10-pin connector.
2.
Align the grooves on the sensor connector (male), with the connector on the
Node (female).
3.
Push the connector into place and then twist the outer ring of the male
connector until it locks.

3.5.3 NOTES CONCERNING MULTI-CHANNEL AND ADDRESSABLE NODES

For ease of wiring, sensor cables should be inserted into the cable glands
on Multi-Channel Nodes from left to right.
Sensors should be wired into the channels of a Node in sequence starting
with channel 1.
Do not wire sensors into the terminal blocks marked '
a Multi-Channel Node.
Multi-Channel Nodes and Addressable Nodes stop trying to read an empty
channel after two attempts. The node will read all channels at the top of
every hour; it will resume sampling when it detects a sensor.
MODEL 8900 SERIES GEONET WIRELESS DATA HOSTING SYSTEM | NETWORK INSTALLATION | 15
VW Single-Channel Node
VW Multi-Channel Node
VW Single/Multi‑Channel Node
Position
Color
VW+
RED
VW−
BLACK
TH+
WHITE
TH−
GREEN
SHD
BARE
485 IN
18:
Description
Vibrating Wire +
Vibrating Wire −
Thermistor +
Thermistor −
Analog Ground (shield)
' and '
' on
485 OUT