APPENDIX E.
FIRMWARE UPDATE
WARNING! Performing a firmware update on a node might reset the node
memory. Retrieve all data from the network prior to performing a
firmware update.
E.1 PROCEDURE
1.
Put the network in deployment mode by pressing the Status button on the
mesh supervisor. For more information on deployment mode see Section 3.7.
Within three minutes the green LED will flash once every 10 seconds.
2.
For RS-232 Supervisors:
a.
Connect the COM-108 (RS-232 cable) to the 10-pin connector on the
Supervisor.
b.
Connect the 8001-7 (USB to RS-232 adapter) to the COM-108.
c.
Connect the 8001-7 to the PC. The figure below shows the completed
connection.

FIGURE 31: RS-232 Cable Connection

3.
For all other nodes/supervisors, connect the COM-166 (Mini USB to STD A
cable) to the USB connector on the bottom of enclosure.

FIGURE 32: USB Cable Connection