4 | NETWORK COMPONENTS | GEOKON
2.3 SINGLE-CHANNEL NODE
A single-channel node will read one
pin cable or via a cable with stripped conductor wires, depending on model.
Though designed to send data wirelessly to a mesh supervisor, this model also
features a USB connector, for transferring data using a USB cable to a PC
running Agent software or other Modbus RTU client.
2.3.1 10-PIN CONNECTOR (890X-XX-01C-10P)
For use with gauges with 10-pin cable connectors.
2.3.2 GLAND SEAL (890X-XX-01C-CBL)
For use with gauge cables that have stripped conductor wires. The gauge cable
passes through an external cable gland and is wired into the terminal block.
FIGURE 3: 10-Pin Single-Channel Node (left) and Gland-Seal Single-Channel Node (right)
2.4 MULTI-CHANNEL NODES
GeoNet multi-channel nodes (MCNs) will read up to four or eight
vibrating wire gauges, depending on model, via cables with stripped conductor
wires. The cables pass through external cable glands and are wired into the
terminal blocks.
Though designed to send data wirelessly to a Supervisor, these models also
feature a USB connector for transferring data using a USB cable to a PC running
Agent software or other Modbus RTU client, just as with single-channel nodes.
2.4.1 FOUR-CHANNEL GLAND SEAL (890X-XX-04C-CBL)
FIGURE 4: Four-Channel Node (890X-XX-04C-CBL)
vibrating wire gauge, either via 10-
GEOKON
3:
GEOKON
4: