INSTALLATIoN
Installation
9.
Installation
9.1
Standard installation
- Electrical connection in the lower section of the appliance for
installation on unfinished walls
- Water connection for installation on unfinished walls
- The switchable connected load is preset to the middle con-
nected load.
For further installation options, see chapter "Installation alter-
natives".
f Open the appliance.
f
f Remove the back panel by pressing the two locking hooks
f
and pulling the lower part of the back panel towards the
front.
Note
If you are installing the appliance with flexible water
connections or water connections on finished walls, ad-
ditionally secure the back panel with a screw.
f Mark out the holes for drilling with the installation template.
f
f Drill the holes and secure the wall mounting bracket with
f
2 screws and 2 rawl plugs (screws and rawl plugs are not
part of the standard delivery).
f Mount the wall mounting bracket.
f
24
| DHE SL LABS
160
30
1 Installation aid
f Prepare the power cable.
f
Making the water connection
Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
f Seal and insert the twin connectors.
f
2
1
2
3
5
4
1 DHW with tee
2 Gasket
3 Cold water with cross-piece
4 Strainer
5 Profile washer
f Fit the water connections.
f
Material losses
!
The strainer must be fitted for the appliance to function.
f When replacing the appliance, check that the strain-
f
er is present.
1