Installation; Standard Installation - STIEBEL ELTRON DHE 18 SL LABS Operation And Installation

Instantaneous water heater with full electronic control
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATIoN

Installation
9.
Installation
9.1

Standard installation

- Electrical connection in the lower section of the appliance for
installation on unfinished walls
- Water connection for installation on unfinished walls
- The switchable connected load is preset to the middle con-
nected load.
For further installation options, see chapter "Installation alter-
natives".
f Open the appliance.
f
f Remove the back panel by pressing the two locking hooks
f
and pulling the lower part of the back panel towards the
front.
Note
If you are installing the appliance with flexible water
connections or water connections on finished walls, ad-
ditionally secure the back panel with a screw.
f Mark out the holes for drilling with the installation template.
f
f Drill the holes and secure the wall mounting bracket with
f
2 screws and 2 rawl plugs (screws and rawl plugs are not
part of the standard delivery).
f Mount the wall mounting bracket.
f
24
| DHE SL LABS
160
30
1 Installation aid
f Prepare the power cable.
f
Making the water connection
Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
f Seal and insert the twin connectors.
f
2
1
2
3
5
4
1 DHW with tee
2 Gasket
3 Cold water with cross-piece
4 Strainer
5 Profile washer
f Fit the water connections.
f
Material losses
!
The strainer must be fitted for the appliance to function.
f When replacing the appliance, check that the strain-
f
er is present.