9. ELECTRICAL CONNECTION AND SETTING FOR ONE TANK
For operation of the AQUATWIN TOP in configuration with a single rain water collection tank, proceed as
follows:
Connect the float (- G1) in the rain water collection tank to the terminals ( 1- 2 ) and set the control unit
(MC1) in 1 TANK mode with the button (
N.B. In the case of a single tank the two intakes can be combined in a single suction pipe.
10.
ELECTRICAL CONNECTION AND SETTING FOR TWO TANKS
For operation of the AQUATWIN TOP in configuration with two separate rain water collection tanks, proceed
as follows:
Connect the float (-G1) in the first rain water collection tank to the terminals (1-2)
Connect the float (-G2) in the second rain water collection tank to the terminals (3-4) and
Set the control unit (MC1) in 2 TANKS mode with the button (
N.B. The pipes must be separate, one for each tank.