DAB AQUATWIN TOP 132 Instruction For Installation And Maintenance page 37

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 33
5. TECHNICAL DATA
Max flow rate (lt/min)
Head Hm max
Pumped liquid temperature
Maximum system pressure
Maximum mains pressure
Supply voltage
Maximum absorbed power
IP protection class
Ambient temperature
Structure material
Tank material
Mains connection
dimension
Intake connection
dimension
Delivery connection
dimension
Overflow connection
dimension
Max. altitude m
Type of water
No-load weight
Overall dimensions
(wxhxd)mm
6. PLUMBING INSTALLATION
ATTENTION!
In the premises where the AQUATWIN TOP is to be installed, it is indispensable to have a suitably sized
drain in order to eliminate any bursts of the system, or excess water from the overflow siphon provided. The
dimensions of the drain or drainage system must be suited to the quantity of water supplied by the mains.
Make sure that the work surface is as uniform as possible, however it will be possible to level the system with
its adjustable feet.
1
2
3
4
ENGLISH
AQUATWIN
TOP 132
80+80
48
Da +5°C a +35°C
10 bar
10 bar
1x230 50Hz
2,1kW
40
min +5°C max +40°C
Cataphoresis treated
steel
Polyethylene clearflex
RL50
1"F
1"F
1"1/2M
2"M
1000
Rain water/non drinking
115
811x1412x813
Fig.3
35
4
AQUATWIN
TOP 40/50
80+80
57,7
Da +5°C a +35°C
10 bar
10 bar
1x230 50Hz
1,6kW
40
min +5°C max +40°C
Cataphoresis treated
steel
Polyethylene clearflex
RL50
1"F
1"F
1"1/2M
2"M
1000
Rain water/non drinking
115
811x1412x813
The plumbing installation comprises the
following connections
1. 1" connection from the mains
(drinking water).
2. 2" connection for the overflow of the
water storage tank.
3. 1½" connection for feeding the
utilities circuit (may be fitted on right
or left of the system).
3
4. 1" connections for intakes from one
or two rain water tanks.
N.b. the two intakes are independent
AQUATWIN
TOP 40/80
120+120
59
Da +5°C a +35°C
10 bar
10 bar
1x230 50Hz
2,1kW
40
min +5°C max +40°C
Cataphoresis treated
steel
Polyethylene clearflex
RL50
1"F
1"F
1"1/2M
2"M
1000
Rain water/non drinking
115
811x1412x813