works for 2 directions. The torque is calculated
from the internal current measurement in the
2
2
frequency converter.
Speed/torque reference
The reference to these controls can be either a single
reference or the sum of various references including
relatively scaled references. Reference handling is explained
in detail in chapter 2.4 Reference Handling.
Process control
There are 2 types of process control:
Process closed-loop control, which runs speed
open-loop to control the motor internally, is a
basic process PID controller.
Extended PID speed open-loop control, which
also runs speed open-loop to control the motor
internally, extends the function of the basic
process PID controller by adding more functions.
For example, feed forward control, clamping,
reference/feedback filter, and gain scaling.