Anritsu Site Master S113BQ Maintenance Manual
Anritsu Site Master S113BQ Maintenance Manual

Anritsu Site Master S113BQ Maintenance Manual

Antenna and cable analyzers

Advertisement

Quick Links

Figure 1. Site Master Model S113BQ
1.
INTRODUCTION
This manual provides maintenance instructions for the Site
Master S113BQ Antenna and Cable Analyzer. It describes
the product and provides performance verification proce-
dures, parts replacement procedures, and a replaceable parts
list.
2.
DESCRIPTION
The Site Master S113BQ (Figure 1) is a hand held SWR/RL
(standing wave ratio/return loss), and Distance-To-Fault
measurement instrument. It combines a synthesized source,
VSWR Bridge, and receiver on a single printed circuit board
(PCB). An optional power monitor is also available. A block
diagram is shown in Figure 2.
490 JARVIS DRIVE · MORGAN HILL, CA 95037-2809
MAINTENANCE MANUAL
Model S113BQ
Site Master™
Antenna and Cable Analyzers
Site Master S113BQ
1000.00
2.00
400.43 MHz
791.12 MHz
MODE
FREQ/DIST
AMPLITUDE
SWEEP
3.
Paragraphs 4 through 9 contain tests that can be used to ver-
ify the performance of the Site Master Model S113BQ.
3.1.
ESCAPE
1
2
CLEAR
START
AUTO
CAL
SCALE
3
4
SAVE
RECALL
SETUP
SETUP
5
6
LIMIT
MARKER
ENTER
7
8
SAVE
RECALL
RUN
DISPLAY
DISPLAY
HOLD
+
9
0
/
-
PRINT
ON
SYS
OFF
.
PERFORMANCE VERIFICATION
Initial Setup for Testing
1.
Press and hold the
ESCAPE/CLEAR
press the
key to turn on the Site Mas-
ON/OFF
ter. (This sets the instrument to the factory pre-
set state.)
2.
Release the
ESCAPE/CLEAR
Up/Down arrow key to adjust the contrast to
give a readable display.
COPYRIGHT ã 2004 ANRITSU CO.
key, then
key and use the
P/N: 10580-00121
REVISION A
PRINTED: AUGUST 2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Site Master S113BQ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Anritsu Site Master S113BQ

  • Page 1 Site Mas- ON/OFF ter. (This sets the instrument to the factory pre- The Site Master S113BQ (Figure 1) is a hand held SWR/RL set state.) (standing wave ratio/return loss), and Distance-To-Fault Release the...
  • Page 2: Frequency Accuracy

    Site Master is not required for this test. MS2663C or equivalent. Set up the Spectrum Analyzer as follows: Equipment Required: (a) Press the key, then select Preset Preset · Spectrum Analyzer Anritsu Model MS2663C (F1). or equivalent (b) Press the key. Frequency Procedure: (c) Press the...
  • Page 3: Return Loss Verification

    Reference Level to 0 dBm. Equipment Required: (l) Press the soft key (F5) Log Scale · 20 dB offset, Anritsu SC5270 (m) Select (F3) and the press the 2 dB/Div soft key (F6). · 6 dB offset, Anritsu SC5237...
  • Page 4 · RF Reference Source, 0.050 GHz, Anritsu MA2418A Connect the output of the MA2418A Reference Source to the two attenuators so as to add 40 · DC Power Supply, Anritsu 2000-933 dB of attenuation (Figure 3). Procedure Connect the MA2418A Reference Source and...
  • Page 5 · Precision Airline, Anritsu 18N50 Press the Channel 2 Display On/Off key to Off. · Open/Short, Anritsu 22N50 Press the Channel 1 Menu key. · 50 Ohm Termination, Anritsu 26N50 Using the Menu up-down keys: Highlight PRE- · Source Adapter, Anritsu 34NN50A , then press the key.
  • Page 6 Short to the beadless end of the air- line. Press the key to start the calibration Select process. At the next menu prompt, remove the Short and connect the 50 Ohm Termination to the Site Master S113BQ MM...
  • Page 7: Battery Pack Removal And Replacement

    Lift the door and remove, as illustrated in Figure 9. BATTERY CONTACTS Grasp the battery lanyard and pull the battery straight up and out of the unit, as illustrated in Fig- ure . Figure 11. Battery Orientation Site Master S113BQ MM...
  • Page 8: Battery Information

    Site Mas- · Do not dispose of batteries in a fire! ter or in the optional battery charger (Anritsu part num- · Batteries must be recycled or disposed of properly. Do ber: 2000-1029).
  • Page 9: Front Panel Assembly Removal And Replacement

    Carefully depress the latch tab and disconnect the LCD display cable from J12 on the main PCB. Carefully disconnect the keypad interface cable from J1 on the main PCB. Carefully disconnect the LCD display backlight ca- ble from J15 on the main PCB. Site Master S113BQ MM...
  • Page 10: Lcd Assembly Replacement

    Remove the rubber cushion pad from the LCD as- Figure 16. Front Panel Keypad PCB Location sembly and remove the assembly. Reverse the above steps to install the replacement Reverse the above steps to install the replacement assembly. assembly. Site Master S113BQ MM...
  • Page 11: Key Pad Membrane Replacement

    NOTE The main PCB connector panel fits into grooves in the two halves of the Site Mas- ter case. Make sure the panel is correctly aligned with the grooves before reassem- bling the two halves together. Site Master S113BQ MM...
  • Page 12: Replaceable Parts

    Foam, LCD Corners & Battery 790-518 Gasket 48278 Foam, LCD Window 52737-3 Keypad PCB Assy 46659 Foam, LCD Backing 46649-1 Membrane Keypad, Main 46661 Foam, Keypad Backing 720-19 Cable Clamp 790-515 Spring, Battery Compartment 52035 ID Label, Model S113BQ Site Master S113BQ MM...
  • Page 13 Table 2. Anritsu Service Centers UNITED STATES FRANCE KOREA ANRITSU COMPANY ANRITSU S.A ANRITSU CORPORATION LTD. 490 Jarvis Drive 9 Avenue du Quebec Service Center: Morgan Hill, CA 95037-2809 Zone de Courtaboeuf 8F Hyunjuk Building Telephone: (408) 776-8300 91951 Les Ulis Cedex...
  • Page 14 NOTES Site Master S113BQ MM...