Anritsu Site Master S113C Maintenance Manual
Anritsu Site Master S113C Maintenance Manual

Anritsu Site Master S113C Maintenance Manual

Antenna and cable analyzers
Hide thumbs Also See for Site Master S113C:

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

loading
Need help?

Need help?

Do you have a question about the Site Master S113C and is the answer not in the manual?

Questions and answers

Summary of Contents for Anritsu Site Master S113C

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2: Performance Verification

    PERFORMANCE VERIFICATION This manual provides maintenance instructions for Paragraphs 4 through 9 contain tests that can be the Site Master S113C/S331C and S115BQ Antenna used to verify the performance of the Site Master and Cable Analyzer. It describes the product and...
  • Page 3: Frequency Accuracy

    Connect the RF cable from the Site Mas- ter Reflection Test Port to the RF Input Equipment Required: on the MS2663C or equivalent. · Spectrum Analyzer Anritsu Model Set up the Spectrum Analyzer as follows: MS2663C or equivalent Preset Pre-...
  • Page 4: Return Loss Verification

    Site Master is required for this test. turn the VB filter off. Equipment Required: Amplitude (j) Press the key. · 20 dB offset, Anritsu SC5270 (k) Press the , and keys sequen- tially to change the Reference Level · 6 dB offset, Anritsu SC5237 to 10 dBm.
  • Page 5 · RF Reference Source, 0.050 GHz, Verify that the power monitor reading is Anritsu MA2418A 0.0 dBm ± 1 dB. · DC Power Supply, Anritsu 2000-933 Connect the output of the MA2418A Ref- erence Source to the two attenuators so Procedure as to add 40 dB of attenuation (Figure 3).
  • Page 6: Instacal Module Verification

    NOTE INSTACAL MODULE VERIFICATION If this particular InstaCal module has been This test verifies the performance of the Anritsu Site used to calibrate this Site Master before, the Master InstaCal Calibration Module. The InstaCal Site Master senses the familiar InstaCal mod-...
  • Page 7 · Precision Airline, Anritsu 18N50 Enter quency to 4.0 GHz. Press the · Open/Short, Anritsu 22N50 key. · 50 Ohm Termination, Anritsu 28N50-2 Press the Channel 2 Display On/Off key to Off. · Source Adapter, Anritsu 34NN50A Press the Channel 1 Menu key.
  • Page 8 Press the key to On. 4 0 1 p t s Observe the Cursor menu readout. The Figure 5. Example of a Good Connection minimum return loss reading for the SM/PL termination should be 42 dB. Site Master S113C/S331C/S115BQ MM...
  • Page 9: Battery Pack Removal And Replacement

    Lift the door and remove, as illustrated in Figure 11. Grasp the battery lanyard and pull the bat- tery straight up and out of the unit, as illus- trated in Figure 9. Figure 11. Battery Orientation Site Master S113C/S331C/S115BQ MM...
  • Page 10: Battery Information

    The LED and the 2000-1029). Battery Charging LED will light. · Use only Anritsu approved battery packs. Disconnect the AC-DC Adapter when the · Recharge the battery only in the Site Master or Battery Charging LED turns off, indicating in an Anritsu approved charger.
  • Page 11: Front Panel Assembly Removal And Replacement

    Figure 14. Site Master Front Panel Cable Connections nected first. Carefully depress the latch tab and discon- nect the LCD display cable from J12 on the main PCB. Carefully disconnect the keypad interface ca- ble from J4 on the main PCB. Site Master S113C/S331C/S115BQ MM...
  • Page 12: Lcd Assembly Replacement

    Remove the rubber cushion pad from the Figure 16. Front Panel Keypad PCB Location LCD assembly and remove the assembly. Reverse the above steps to install the re- Reverse the above steps to install the re- placement assembly. placement assembly. Site Master S113C/S331C/S115BQ MM...
  • Page 13: Key Pad Membrane Replacement

    PCB. NOTE The main PCB connector panel fits into grooves in the two halves of the Site Master case. Make sure the panel is correctly aligned with the grooves before reassembling the two halves together. Site Master S113C/S331C/S115BQ MM...
  • Page 14: Replaceable Parts

    Option 05 720-19 Cable Clamp 47812-3 Keypad PCB Assy 790-515 Spring, Battery Compartment 46649-1 Membrane Keypad, Main 55216 ID Label, Model S113C 633-26 Lithium Coin Clock Battery 55223 ID Label, Model S331C 55224 ID Label, Model S115BQ Site Master S113C/S331C/S115BQ MM...
  • Page 15 NOTES...
  • Page 16 Table 2. Anritsu Service Centers UNITED STATES FRANCE SINGAPORE ANRITSU COMPANY ANRITSU S.A ANRITSU (SINGAPORE) PTE LTD 685 Jarvis Drive 9 Avenue du Quebec 10, Hoe Chiang Road Morgan Hill, CA 95037-2809 Zone de Courtaboeuf #07-01/02 Telephone: (408) 776-8300 91951 Les Ulis Cedex...

This manual is also suitable for: