6 Interface signal

6.1 RS-232 interface (optional)

6.1.1 Parameter

1)
Data transfer mode: asynchronous serial communication
2)
Handshaking mode: RTS/CTS
3)
Level:
MARK= -3 to -15 V: Logic "1"/ OFF
i.
4)
Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600 bps
5)
Data bit:
8 bit or 7 bit
6)
Parity checkout: None, even, or odd
7)
Stop bit:
1bit
8)
Connector: 9-pin serial interface connector (female type)
Note: Serial baud rate, data bit and parity bit are set by EEPROM.

6.1.2 Interface linking terminal distribution and signal function

Printer signal and status is described as the following table:
Pin
1
2
3
4
5
6
7
8
9

6.1.3 Demonstration of interface connection

Note: Please send data to the printer after the printer is powered on and finishes initializing.
SPACE = +3 to +15 V: Logic "0"/ ON
Signal name
Signal direction
RXD
TXD
DTR
SG
DSR
RTS
CTS
FG
Table 6.1.2 Interface and pin explanation
Host side
TXD---------------RXD
RXD---------------TXD
DSR---------------DTR
CTS---------------RTS
RTS---------------CTS
DTR---------------DSR
FG ---------------FG
SG ---------------SG
Input
Output
Output
Output
Input
Printer side
- 41 -
BT-T080R User's Manual
Function
Receive data
Transmit data
Data terminal ready
Signal ground
Data set ready
Request to send
Allow to send
Frame ground