TEMPERATURE SENSOR DATA
Temperature (°C)
Resistance
(kOhm)
-40
351.0
-35
251.6
-30
182.5
-25
133.8
-20
99.22
-15
74.32
-10
56.20
-5
42.89
0
33.02
5
25.61
10
20.02
15
15.77
20
12.51
25
10.00
30
8.045
35
6.514
40
5.306
45
4.348
50
3.583
55
2.968
60
2.467
65
2.068
70
1.739
75
1.469
80
1.246
85
1.061
90
0.908
95
0.779
100
0.672
PULLING OUT THE COOLING MODULE
The cooling module can be pulled out for service and
transport.
NOTE
Switch off the heat pump and cut the power
with the safety switch.
Caution
Remove the front cover according to the de-
scription on
page
62
Chapter 9 | Service
Voltage (VDC)
3.256
3.240
3.218
3.189
3.150
3.105
3.047
2.976
2.889
2.789
2.673
2.541
2.399
2.245
2.083
1.916
1.752
1.587
1.426
1.278
1.136
1.007
0.891
0.785
0.691
0.607
0.533
0.469
0.414
8.
1.
Close the shut-off valves (QM31), (QM32), (QM33)
and (QM34).
Drain the compressor module according to the in-
structions on
page 60
F1245
Pull off the lock catches.
2.
Disconnect the pipe connection under the shut-off
3.
valve (QM31).
QM31
3
4.
Remove the two screws.
Remove the connections from the base card (AA2)
5.
using a screwdriver.
Disconnect the connectors (A) and (B) from the un-
6.
derside of the base card cabinet.
QM31
QM33
QM34
QM32
2
4
5
NIBE F1245

Advertisement

Table of Contents
loading