MENU 5.1.22 - HEAT PUMP TESTING
NOTE
This menu is intended for testing F1245 accord-
ing to different standards.
Use of this menu for other reasons may result
in your installation not functioning as intended.
This menu contains several sub-menus, one for each
standard.
MENU 5.2 - SYSTEM SETTINGS
Make different system settings for the heat pump here,
e.g. master/slave settings, docking settings and which
accessories are installed.
MENU 5.2.1 - MASTER/SLAVE MODE
Setting range: master, slave 1-8
Default value: master
Set the heat pump as master- or slave unit. In systems
with one heat pump it must be "master".
Caution
In systems with several heat pumps, each
pump is allocated a unique ID. In other words,
only one heat pump can be "master" and only
one can be "slave 5".
MENU 5.2.2 - INSTALLED SLAVES
Set which slaves are connected to the master heat
pump.
There are two ways of activating connected slaves. You
can either mark the alternative in the list or use the
automatic function "search installed slaves".
search installed slaves
Mark "search installed slaves" and press the OK button
to automatically find connected slaves for the master
heat pump.
NOTE
Before these settings are made, each slave
must have received a unique ID (see menu
5.2.1).
MENU 5.2.3 - DOCKING
Enter how your system is docked regarding pipes, for
example to pool heating, hot water heating and building
heating. The menu is only displayed if at least one slave
is connected to the master.
NIBE F1245
This menu has a docking memory which means that the
control system remembers how a particular reversing
valve is docked and automatically enters the correct
docking the next time you use the same reversing valve.
Master/slave
master
s1
s2 s3 s4 s5 s6 s7 s8
F1245
Compressor
Master/slave: Select the heat pump for which the
docking setting is to be made (if there is only one heat
pump in the system, only master is displayed).
Compressor: Here, you select whether the compressor
is blocked, externally controlled via soft input or standard
(docked for example to pool heating, hot water charging
and heating the building).
Marking frame: Move around the marking frame using
the control knob. Use the OK button to select what you
want to change and to confirm the setting in the options
box that appears to the right.
Workspace for docking: The system docking is drawn
here.
Symbol
Description
Compressor (blocked)
Compressor (externally controlled)
Compressor (standard)
Reversing valves for hot water, cooling re-
spectively pool control.
The designations above the reversing valve
indicate where it is electrically connected
(EB100 = Master, EB101 = Slave 1, CL11
= Pool 1 etc.).
Own hot water charging, only from selected
heat pump compressor. Controlled by relev-
ant heat pump.
Pool 1
Chapter 8 | Control - Menus
Workspace for docking
docking5.2.3
Marking frame
51