Nibe F1245 Series Installation Manual page 47

Ground source heat pump
Hide thumbs Also See for F1245 Series:
Table of Contents

Advertisement

Sub-menus
Menu
SERVICE
has orange text and is intended for the
advanced user. This menu has several sub-menus.
Status information for the relevant menu can be found
on the display to the right of the menus.
operating settings
Operating settings for the heat
pump.
system settings
System settings for the heat pump,
activating accessories etc.
accessory settings
Operational settings for different
accessories.
soft in/outputs
Setting software controlled in and out-
puts on the input circuit board (AA3).
factory setting service
Total reset of all settings (includ-
ing settings available to the user ) to default values.
forced control
Forced control of the different compon-
ents in the heat pump.
start guide
Manual start of the start guide which is run
the first time the heat pump is started.
quick start
Quick starting the compressor.
NOTE
Incorrect settings in the service menus can
damage the heat pump.
MENU 5.1 - OPERATING SETTINGS
Operating settings can be made for the heat pump in
the sub menus.
MENU 5.1.1 - HOT WATER SETTINGS
start temp. economy / normal / lux
Setting range: 5 – 70 °C
Factory setting (°C):
kW
Enamel
5
6
8
10
12
Copper
5
6
8
10
12
Stainless
5
6
8
10
12
NIBE F1245
eco-
normal
luxury
nomy
41
44
47
40
43
46
39
42
45
37
40
43
36
39
42
42
45
48
41
44
47
40
43
46
38
41
44
37
40
43
42
45
48
41
44
47
40
43
46
38
41
44
37
40
43
stop temp. economy / normal / lux
Setting range: 5 – 70 °C
Factory setting (°C):
kW
Enamel
5
6
8
10
12
Copper
5
6
8
10
12
Stainless
5
6
8
10
12
stop temp. per. increase
Setting range: 55 – 70 °C
Factory setting: 55 °C
Here you set the start and stop temperature of the hot
water for the different comfort options in menu 2.2 as
well as the stop temperature for periodic increase in
menu 2.9.1.
If several compressors are available set the difference
between engagement disengagement of them during
hot water charging and fixed condensing.
MENU 5.1.2 - MAX FLOW LINE
TEMPERATURE
climate system
Setting range: 20-80 °C
Default value: 60 °C
Set the maximum supply temperature for the climate
system here. If the installation has more than one cli-
mate system, individual maximum supply temperatures
can be set for each system. Climate systems 2 - 8 can-
not be set to a higher max supply temperature than cli-
mate system 1.
Chapter 8 | Control - Menus
eco-
normal
luxury
nomy
45
48
51
44
47
50
43
46
49
41
44
47
40
43
46
46
49
52
45
48
51
44
47
50
42
45
48
41
44
47
46
49
52
45
48
51
44
47
50
42
45
48
41
44
47
47