MOTOR PROTECTION BREAKER /MINIATURE
CIRCUIT BREAKER
Motor protection breaker (AA11-FC10) / miniature circuit
breaker (AA11-FC1) cuts the power to the compressor
if the current is too high. It is located behind the front
cover and is reset manually.
Caution
Check the miniature circuit-breaker, temperat-
ure limiter and motor protection breaker. They
may have tripped during transportation.
ACCESSIBILITY, ELECTRICAL CONNECTION
The plastic cap of the electrical boxes is opened using
a screwdriver.
NOTE
The cover for the input card is opened without
a tool.
Removing the cover, input circuit board
1
2
1.
Push the catch down.
2.
Angle out the cover and remove it.
22
Chapter 5 | Electrical connections
Removing the cover, immersion heater circuit
board
1
2
Insert the screwdriver (A) and pry the catch carefully
1.
downwards (B).
2.
Angle out the cover and remove it.
Removing the cover, base board
Caution
To remove the cover for the base board, the
cover for the input circuit board must first be
removed.
1
1
2
2
3
A
B
A
B