 Forbid to switch on/off the Power DIP during
operation. Otherwise, it will damage your IPOE-
171S and remote device. If you want to switch
the output Voltage DIP, please Plug OUT the
"POE In" cable and wait for 3 seconds until
the POE LED (Power) is completely OFF.

5.2 4-pin Power Output Terminal Block

From top to down, there are Negative (V-), Negative (V-),
Positive (V+) and Positive (V+), and two sets of DC power
output contact.
Figure 4: Terminal Block of IPOE-171S
Two DC outputs are sharing 12V 2A or 24V 1A,
totaling 55 watts DC output power, which
means that DC1 + DC2 cannot be over the 55
Note
watts DC output power. Otherwise, it might cause
the power output to malfunction or damage.
12
Power Output
V
V
V+
V+
12V
24V
DC Voltage
12V 24V