Carrier AquaForce 30XV140-500 Installation Instructions Manual page 108

Variable speed air-cooled liquid chillers with greenspeed intelligence
Hide thumbs Also See for AquaForce 30XV140-500:
Table of Contents

Advertisement

Table 10 — 30XV160-500 Electrical Data, Single Point Power, Standard Tier, Variable Speed Fans
UNIT VOLTAGE
UNIT
Supplied
30XV
V(3 Ph)
Hz
Min
Max
208/230
60
187
380
60
342
400
60
360
460
60
414
575
60
518
160
380
50
342
400
50
360
415
50
374
440
50
396
208/230
60
187
60
342
380
400
60
360
460
60
414
575
60
518
180
380
50
342
400
50
360
415
50
374
440
50
396
208/230
60
187
380
60
342
400
60
360
460
60
414
575
60
518
200
380
50
342
400
50
360
415
50
374
440
50
396
380
60
342
400
60
360
460
60
414
575
60
518
225
380
50
342
400
50
360
415
50
374
440
50
396
380
60
342
400
60
360
460
60
414
575
60
518
250
380
50
342
400
50
360
415
50
374
440
50
396
380
60
342
400
60
360
460
60
414
575
60
518
275
380
50
342
400
50
360
415
50
374
440
50
396
LEGEND
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
VFD
— Variable Frequency Drive
NOTES:
1. Units are suitable for use on electrical systems where voltage
supplied to the unit terminals is not below or above the listed
minimum and maximum limits. Maximum allowable phase imbal-
ance is: voltage, 2%; amps 10%.
2. Evaporator heater (where applicable) is wired into the control cir-
cuit so it is always operable as long as the control power supply
disconnect is on, even if any safety device is open.
3. For MCA that is less than or equal to 380 amps, 3 conductors are
required.
For MCA between 381-760 amps, 6 conductors are required.
For MCA between 761-1140 amps, 9 conductors are required.
For MCA between 1141-1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
STANDARD CONDENSER FANS
NUMBER
OF COND
FANS
MCA
253
8
680.7
418
8
372.7
440
8
354.8
506
8
307.5
633
8
248.2
418
8
380.3
440
8
362.4
457
8
349.7
484
8
329.5
253
8
781.9
418
8
428.9
440
8
406.6
506
8
353.2
633
8
284.2
418
8
438.8
440
8
418.6
457
8
403.7
484
8
381.2
253
10
812.2
418
10
446.1
440
10
423.2
506
10
367.0
633
10
295.6
418
10
456.1
440
10
435.5
457
10
420.2
484
10
394.9
418
10
511.8
440
10
487.2
506
10
422.2
633
10
338.2
418
10
523.1
440
10
498.5
457
10
480.6
484
10
453.6
418
12
588.9
440
12
558.8
506
12
484.9
633
12
390.0
418
12
601.4
440
12
573.5
457
12
553.3
484
12
520.7
418
12
609.2
440
12
579.0
506
12
502.4
633
12
403.5
418
12
621.7
440
12
591.5
457
12
571.3
484
12
538.7
HIGH STATIC CONDENSER FANS
REC FUSE
MOCP
MCA
SIZE
800
800
691.0
500
450
383.0
450
400
364.9
400
350
316.3
300
300
255.1
500
450
390.8
500
400
372.4
450
400
359.4
450
400
338.6
1000
1000
792.3
500
500
439.3
500
450
416.6
450
400
362.0
350
350
291.1
600
500
449.3
500
500
428.7
500
450
413.4
500
450
390.3
1000
1000
825.1
600
500
459.0
500
500
435.8
500
450
378.0
400
350
304.2
600
600
469.3
600
500
448.0
500
500
432.2
500
450
406.3
700
600
524.8
700
600
499.8
600
500
433.2
450
400
346.8
700
600
536.3
700
600
511.0
700
600
492.7
600
600
465.0
800
700
604.5
700
700
573.9
600
600
498.1
500
450
400.3
800
700
617.3
700
700
588.5
700
700
567.8
700
600
534.4
800
700
624.7
800
700
594.1
700
600
515.6
500
450
413.8
800
700
637.5
800
700
606.5
700
700
585.8
700
600
552.4
4. Based on the operational characteristics of a VFD, the "inrush"
current normally associated with a chiller is limited and will be
lower than the MCA rating of the chiller.
5. Wiring for main field supply must be rated 75 C minimum. Use
copper for all units. Refer to Table 8 for power entry option.
6. MCA and MOCP values shown are inclusive of control power
transformer loads.
108
CONTROL CIRCUIT
Voltage
REC FUSE
MOCP
1 PH,
SIZE
60 Hz
800
800
115
500
450
115
450
400
115
400
350
115
300
300
115
500
450
115
500
450
115
450
400
115
450
400
115
1000
1000
115
500
500
115
500
500
115
450
400
115
350
350
115
600
500
115
500
500
115
500
500
115
500
450
115
1000
1000
115
600
600
115
500
500
115
500
450
115
400
350
115
600
600
115
600
500
115
500
500
115
500
450
115
700
600
115
700
600
115
600
500
115
450
400
115
700
600
115
700
600
115
700
600
115
600
600
115
800
700
115
700
700
115
600
600
115
500
450
115
800
700
115
800
700
115
700
700
115
700
600
115
800
700
115
800
700
115
700
600
115
500
500
115
800
700
115
800
700
115
800
700
115
700
700
115
MCA
and
MOCP
40
40
40
40
40
40
40
40
40
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60