Operation

8.6 Stoppages

8.5

Switching on again after an emergency switching-off

• Check the machine before recommissioning the driven machine after an Emergency Off.
• Eliminate all the causes that have led to the emergency off
8.6
Stoppages
The stoppage is a shutdown for a period of time, during which the machine is stopped but
remains at the location of use.
Under normal ambient conditions, e.g. the stationary machine is not exposed to any vibration,
no increased level of corrosion, ... then the following measures are required.
Longer non-operational periods
Note
• For longer non-operational periods (> 1 month), either operate the machine or at least turn
the rotor regularly, approximately once per month.
• Please refer to the section "Switching on" before switching on to recommission the motor.
• If present, remove the rotor shipping brace before you turn the rotor.
NOTICE
Restricted motor function
If not used for longer periods of time, material damage or complete motor failure can occur.
If the motor is out of service for a period of more than 12 months, then environmental effects
can damage the motor.
• Apply suitable corrosion protection, preservation, packaging and drying measures.
Taking the machine out of service
Details regarding the necessary measures, Chapter Preparing for use (Page 27).
84
Operating Instructions, 07/2020, A5E46712792A
1FU9