3.2.6

Mounting the equipment set

3.2.7

Leakage test

3.2.8

Removing the rotatable rosette

Multiplex Trio drain and overflow functional unit Visign MT5
To avoid damage to the rosette and valve cone, mount the equipment
set only after finishing all other work on the building site. Proceed as fol‐
lows:
Place the flange cover onto the supply flange with the straight side
facing downwards and affix.
Align and fit the rotatable rosette.
Fit the valve cone.
Turn the rotatable rosette to check function and alignment.
The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve
cone using the adjusting screw (see next step).
Set the valve cone with the help of the adjusting screw and counter
with the nut.
The leakage test is only carried out as a visual inspection.
Check the points marked in the following drawing with particular care:
Check for visible leaks.
If the rotatable rosette on the overflow is to be removed, proceed as fol‐
lows to prevent damaging the rosette and the flange cover: