CB1200 Pellet Insert
F. Installation into a Factory-Built Fireplace
The following modifications are permissible:
•
Removal of damper or locked in open position
•
Removal of smoke shelf or baffle
•
Removal of ember catches
•
Removal of fire grate
•
Removal of view screen/curtain
•
Removal of doors
•
Removal of factory-built fireplace floor
•
External trim pieces which do not affect the operation
of the fireplace may be removed providing they can be
stored on or within the fireplace for reassembly if the
insert is removed.
•
The permanent metal warning label provided must be
attached to the back of the fireplace, with screws or
nails, stating that the fireplace may have been altered
to accommodate the insert, and must be returned to
original condition for use as a conventional fireplace.
Figure 12.1
WARNING
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
Heath & Home Technologies
Figure 12.1
250-2061
5.5 in. width x 2 in. height
NON. ANOD. ALUM BLACK LETTERS ON SILVER
•
If the hearth extension is lower than the fireplace
with 1/8 in. holes on both sides.
Black letters
opening, the portion of the insert extending onto the
hearth must be supported.
•
Manufacturer designed adjustable support kit can be
ordered from your dealer.
NOTE: Refer to chimney liner manufacturer for
recommendations on supporting the liner.
Installation into fireplaces without a permit will
void the listing.
•
The firebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory-built firebox in order to gain minimum insert
opening requirements.
•
Any smoke shelves, shields and baffles may be
removed from a factory-built firebox if attached with
mechanical fasteners.
•
The metal floor of the factory-built firebox may be
removed to facilitate the installation of the insert only
when a 1 inch (25mm) airspace is provided between
the insert and the floor of outer wrap.
12
The following is only one example as there are many
different models of factory-built fireplaces.
NOTE: This example is for reference only. Any
modifications must not compromise the structural
integrity or reduce the protection for combustible
materials.
Figure 12.2
Measure and mark the metal floor for cutting. With a drill,
make a starter hole in each corner.
250-2061
250-2061
Figure 12.3
Using a saws-all, cut out the floor.
Figure 12.4
Place the insert into the factory-built firebox. Ensure that
the power cord can not be damaged by the sharp metal
edge. You may need to cut out a notch to accommodate
the cord.
7014-285C
Starter hole
Mark area of
floor to cut
Keep sharp edge of
metal floor away from
power cord
August 1, 2018