Vertical Into Existing Class A Chimney; Through The Wall & Vertical - Exterior; Vertical - Interior - Typical Installation - Quadra-Fire CASTILE-MBK-B Installation Manual

Castile-b pellet appliance
Hide thumbs Also See for CASTILE-MBK-B:
Table of Contents

Advertisement

CASTILE FREESTANDING
B. Vertical into Existing Class A Chimney
Flashing
Firestop
Ceiling Support
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
Figure 16.1
C. Through The Wall & Vertical - Exterior
2 in. (51mm) minimum
6 in. (152mm)
minimum
Non-combustible Hearth Pad
Figure 16.2
16
Rain Cap
24 in. (610mm) Minimum
6 in. (152mm) Class A
Chimney Connector
Adapter
3 in. (76mm) Min.
3 in. to 6 in.
(76-152mm)
Top Vent Kit
Clean-out Cover
Rain Cap
Flashing
24 in. (610mm) minimum
Support Bracket
every 60 in. (1.5m)
Wall Thimble
Tee
Clean-out Cover
We recommend a minimum of 60 inches
(1524mm) vertical, however above the eave
is preferred.
All three installations are approved for mobile
home installations. Must use 3 or 4 inch (76
to 102mm) "L" or "PL" Listed pellet venting or
Listed double wall pipe and Quadra-Fire Outside
Air Kit in mobile homes. Single wall pipe is
approved for residential installations only.
*NOTE: Clearance to combustibles are for
standard pellet pipe. If pellet pipe manufacturer
allows reduced clearances to their pipe, reduced
clearances are allowed.
6 in. (152mm) Flue
Connector
A chimney connector shall not pass through an
attic or roof space, closet or similar concealed
space, or a floor or ceiling.
D. Vertical - Interior - Typical Installation
1 in. (25mm) clearance
with firestop
6 in. (152mm)
minimum
Non-combustible Hearth Pad
Figure 16.3
7021-154J
NOTE:
Concrete Cap
1 in. (25mm)
clearance
3 in. (76mm)
minimum
Clean-out cover
Fireclay flue
liner with airspace
Flashing
Sheathing
Airtight
Clean-out Door
May 12, 2017