Advertisement

Quick Links

• Important operating and
maintenance instructions
included.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.

- Do not try to light any appliance.

Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory-trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Page 1
COLUMBIA BAY
DIRECT VENT GAS APPLIANCE
Owner's Manual
Installation and Operation
Model:
COLBAY-FS-B
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and
follow these instructions
for safe installation and
operation.
fi re
Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11
R
• Leave this manual with
party responsible for use
and operation.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or gas
fi tter.
See Table of Contents for additional Commonwealth of Mas-
sachusetts requirements.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
O-T L
Tested and
Portland
Oregon USA
Listed by
C
US
OMNI-Test Laboratories, Inc.

Advertisement

loading
Need help?

Need help?

Do you have a question about the COLBAY-FS-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Quadra-Fire COLBAY-FS-B

  • Page 1: Do Not Try To Light Any Appliance

    Technologies suggests NFI certifi ed or factory-trained CAN/CSA Z240MH. professionals, or technicians supervised by an NFI This appliance is only for use with the type(s) of gas indicated certifi ed professional. on the rating plate. Page 1 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 2 DO NOT REMOVE THIS LABEL / NE PAS Date of Manufacture / Date du Manufacturier ENLEVER L’ÉTIQUETTE 2005 2006 2007 Made in U.S.A. / Fait Aux États-Unis Date 250-5184 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 2...
  • Page 3 C. Vent Components List ......43 A. Fuel Conversions ........22 D. Service Parts List ........44 B. Gas Pressures ........24 E. Warranty ..........47 C. Gas Connection........24 F. Contact Information ......49 = Contains updated information. Page 3 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 4 Page 4 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 5 The sign shall read, in print size no ance or equipment at the completion of the installation. less than one-half (1/2) inch in size, “GAS VENT DIRECTLY Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 5...
  • Page 6 Framing Material Flat Blade Screwdriver Voltmeter Plumb Line Gloves Level Safety Glasses Manometer Non-corrosive Leak Check Solution or combustible gas detector Tape Measure Caulking material (300ºF minimum continuous exposure rating) Page 6 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 7 USE wood fl ooring, ceramic tile, brick hearth manufacturer for maximum temperature allowed on flooring or high pressure laminate fl ooring applied surfaces. directly over the sub-fl ooring material. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 7...
  • Page 8 In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap. Page 8 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 9 NOTE 3: Location of the vent termination must not interfere with access CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH to the electrical service. VINYL SIDING, IT IS SUGGESTED THAT A VINYL PRO- TECTOR KIT BE INSTALLED (part #VPK-DV). Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 9...
  • Page 10 Vertical terminations are measured to the top of the last May impair safe operation of this appliance or pipe before termination cap. other appliances connected to the fl ue. • Horizontal pipe installed level with 1/4 in. rise. Page 10 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 11 9 ft. (3 -1 = 2 elbows x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. maximum). EX. 2 VERTICAL DISTANCE FROM APPLIANCE TO EX. 1 11" 2' 14' 15' (MAX) (MIN) Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 11...
  • Page 12 The female locking lugs may not be visible from the outside, on the pipe or fittings. They may be located by examining the inside of the female ends. Page 12 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 13 Vent terminal shall not be recessed into a arrow on the vent cap should be pointing up ( wall or siding. Remove siding from the area where the standoff will be located. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 13...
  • Page 14 Note: The attachment from the vent pipe to the vent termination cap must be sealed with silicone with a minimum of 300ºF continuous exposure rating. Termination caps shall not be recessed into a wall or siding. Page 14 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 15 Maintain vent clearance to combustibles as speci- fi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fi re. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 15...
  • Page 16 Step 2. Frame the hole as shown in CEILING JOISTS FRAMING ROUND CEILING SUPPORT BOX/WALL THIMBLE COVER 1-1/2 in. (38mm) LONG WOOD SCREWS Page 16 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 17 ). The opening should be framed to 10 in. x 10 in. (254mm x 254mm) inside dimensions, in the same manner as shown in , on page 16. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 17...
  • Page 18 Ensure that all pipe and elbow connections are in their CATHEDRAL fully twist-locked position. Assemble as instructed. CEILING SUPPORT SCREWS Page 18 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 19 Pipe with sheet metal screws. The connection between the appliance and the retro connector may be completed with sections of direct vent pipe. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 19...
  • Page 20 This allows the retro connector to mount directly on the line up the flex liner with the vent opening on the appliance. masonry and provide the correct clearances to combustibles Page 20 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 21 WALL THIMBLE COVER THREE SHEET METAL SCREWS FOUR MASONRY BOLTS (NOT INCLUDED) The connection between the appliance and the retro connector may be completed with sections of direct vent FLASHING pipe. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 21...
  • Page 22 It is helpful to remove the nut completely. Slide the shutter to appropriate injector (35 LP, 62 NG). the right (closed position). Reinstall the burner, and reassemble the appliance. Page 22 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 23 The installation is not proper and complete until the operation of the converted appliance is checked as specifi ed in the manufacturer’s instructions supplied with the kit. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 23...
  • Page 24 You must supply a manual shut-off valve in a visible location the suggested input pressure listed above. Contact the local within 3 feet (914mm) of the appliance. gas supplier if the regulator is at an improper pressure. Page 24 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 25 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 25...
  • Page 26 18 feet Keep wire lengths as short as possible by removing any excess wire length. Low voltage and 110 VAC voltage cannot be shared within the same wall box. Page 26 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 27 • Replace damaged wire with type 105 Wiring errors can cause improper and dangerous operation. rated wire. Verify proper operation after servicing. • Wire must have high temperature insulation. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 27...
  • Page 28: Appliance Setup

    To remove existing metal refractory remove the two screws located on the left and the two on the right sides behind the side curtains. Page 28 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 29 Install the left and right brick panels. Use the screw placement shown in to secure them in place. Reassemble appliance. Insert locator pin in rear log. Insert rear log onto log pan over stud. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 29...
  • Page 30 Improperly placed embers interferes with proper burner operation. Place individual pieces of embers in front of and around the gas log where they can be seen. Space them so Page 30 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 31 Turn power supply back on. Fan Speed Snap Disk Control WHITE WHITE BLACK BLACK BLACK F = Female M = Male BLACK Power Cord (110 VAC) Ground BLACK Strain Relief Bushing Fan Assembly Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 31...
  • Page 32 Make adjustment until flame size and activity suits your personal preference, and then retighten screws on adjustment control. NOTE: In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor. Page 32 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 33 • CAREFULLY SUPERVISE children in same room as fi replace. • Alert children and adults to hazards of high temperatures. fl • Keep clothing, furniture, draperies and other fl ammable materials away. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 33...
  • Page 34 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position. Page 34 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 35 Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the appliance. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 35...
  • Page 36 With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads. The reading should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Page 36 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 37 Ensure that no debris has been placed at the base of, or in the area of the air holes in the center of the base pan beneath the burner. Ensure that the glass is tightened properly on the appliance, particu- larly on top corners. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 37...
  • Page 38 • Exposure to combustion fumes • Odors Inspect external vent cap regularly. • Ensure no debris blocks cap. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Page 38 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 39 4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and fl ashing remains intact. Remote Controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 39...
  • Page 40 Page 40 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 41 Dimensions are actual appliance dimensions. Use for reference only. For clearances refer to Section 3. 22-1/2 11-1/4 28-1/2 7-3/4 18-3/4 17-7/16 28-1/2 22-1/2 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 41...
  • Page 42 6-9/16 in. 6-9/16 in. 6-9/16 in. 6-9/16 in. 167 mm 167 mm 167 mm 167 mm SLP48 SLP12 SLP36 SLP24 Note: Pipes overlap 1-3/8 inches (34.93 mm) at each joint. Page 42 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 43 SL-SCD Storm Collar SLP-FS Ceiling Firestop SLP-WS Wall Firestop SLP-HVS Pipe Support Hanger Vinyl Protector Kit - SL Pipe DRC-RADIUS Decorative Radius Cover HTI-DV-WT Wall Thimble RF4-8 Roof Flashing Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 43...
  • Page 44 3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11 Page 47...
  • Page 45 (continued) WARRANTY CONDITIONS: WARRANTY EXCLUSIONS: This warranty is void if: LIMITATIONS OF LIABILITY: 4021-645C 12-29-10 Page 2 of 2 Page 48 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...
  • Page 46: Contact Information

    This product may be covered by one or more of the following patents: (United States) 5328356, 5601073, 5613487, 5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Page 49 Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11...