Start-Up Instructions; Shut-Down Instructions - L.B. White Guardian AD060 Owner's Manual And Instructions

Agricultural animal confinement building brood heater, propane-vapor withdrawal, butane, propane withdrawal or natural gas
Hide thumbs Also See for Guardian AD060:
Table of Contents

Advertisement

Start-Up Instructions

Follow steps 1 - 6 on initial start-up after brood
person. For normal start-up, simply turn thermostat
above room temperature. The brood heater will start.
1. Open all manual fuel supply valves and check for
gas leaks using approved leak detectors. The gas
control valve on the brood heater has a manual
shut-off feature incorporated into the valve as-
sembly. Make sure the indicator on the valve is
turned to the "on" position. See Fig. 6.
FIG. 6
OFF
2. Connect the electrical cord to an approved
electrical outlet.
3. Set the thermostat (if supplied) to desired room
temperature.
4. This brood heater includes a direct ignition control
module for purposes of controlling the timing
of the ignition process of the heater as well as
monitoring of the safety functions. The control
module is contained within the control enclosure.
On the control module is a red light emitting diode
(LED). This LED indicates the status of the brood
heater. The LED is visible external of the control
enclosure through the viewing window. A constant
light from the LED is an indicator that the brood
by the LED is indicative that there is a problem
in the operation of the brood heater. Refer to the
troubleshooting decal on the access panel at the
fan motor end of the brood heater for assistance
trained personnel shall service or repair the brood
heater.
Guardian Brood Heaters
5. On a call for heat, the motor will start up and run
feature and a normal operational characteristic
the igniter will begin to spark.
NOTE: It is normal for air to be trapped in the gas
hose on new installations. The brood heater may at-
tempt more than one trial for ignition before the air is
6. The ignition control will make up to three trials for
ignition. Each trial for ignition will take approxi-
ignition will occur within 40 seconds if ignition is not
achieved. A 15 minute "wait period" will then begin
after the third trial for ignition has taken place.
After the 15 minute time span has elapsed, three
more trials for ignition will take place. If ignition is
ON
the LED.

Shut-Down Instructions

If the brood heater is to be shut down for cleaning,
maintenance or repair, follow steps 1 - 5. Otherwise,
simply turn thermostat to "off" or "no heat" for stan-
dard shut down.
1. Close all manual fuel supply valves.
2. With the brood heater lit, allow heater to burn off
excess fuel in gas supply hose.
3. Turn the indicator on the gas control to "off".
4. Turn thermostat to "off" or "no heat" position.
5. Disconnect the brood heater from the electrical
supply.
Owner's Manual • Guardian