Operation & Filter Maintenance
4.
Operation & Filter Maintenance
4.01

Starting the Hood

Be sure that all filters are in place and access doors are closed and latched securely before attempting to operate
the unit. NOTE: Hood will NOT power‐up if either Filter Door is open, or ajar.
To Start the Hood:
1.
Press and momentarily hold the top [START] portion of the Power Switch ① until the hood blower starts running.
Release and switch will spring back to remain ON.
2.
An alarm may sound briefly, then silence when blower reaches full speed.
3. Both E.A.C. Status [ON] lights ② will turn ON. Cooking appliances under the hood should now be receiving
power and ready for use.
4. Place Light Switch ③ in the [ON] position to turn on the under‐hood lights.
To Shutdown the Hood:
1. Press the bottom [OFF] portion of the Power Switch ①.
2
Blower stops and all indicator lights turn OFF.
3. Power to the appliances is shutdown.
4.02
Filter System, Filter Maintenance & Filter Alarms

4.02.1 Ventless Hood Filter Table

Filter
Baffle Filter
Pre‐Filter
E.A.C. Collector Cell
Replace every 30 to 40
Charcoal Filter
When to
Clean/Replace
Clean daily
Replace every 7 to 10
days
Clean daily
days,
2
How to Remove
Section 4.02.2
DO NOT attempt to
Section 4.02.4
clean; ONLY replace!
Section 4.02.6
DO NOT attempt to
Section 4.02.8
clean; ONLY replace!
Model: FSH-6
1
3
How to Clean
How to Install
Section 4.04.1
Section 4.02.3
Section 4.02.5
Section 4.03.4
Section 4.04.2
Section 4.02.7
Section 4.02.9
Section 4.03.5
25