Zenith HydroChill HCF90NZ Installation Instructions & User Manual page 33

Table of Contents

Advertisement

Performance Data Sheet
Zenith GlobalPlus Water Filter ZGP 65S
Zip GlobalPlus Water Filter ZGP 65S
Part number 92323NZ
Part number 92323
These systems have been tested according to NSF/ANSI Standard 42 and/ or AS/NZS 4348 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and/ or AS/NZS 4348
Contaminant Reduction
Chlorine taste and odour
Application guidelines / water supply parameters
Capacity
Service flow
Water pressure
Water temperature
Warning: AS3497:1998 requires dual backflow prevention and
certified pressure control device to be installed prior to filter system(s)
that are plumbed into mains water supply. Failure to do so will not
only void all warranty(s) on the filter system(s), but will put the home
at risk of flooding in the event of damaged appliances during pressure
surges.
Caution: Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
To reduce the risk associated with property damage due to water
leakage:
• Read and follow instructions before installation and use of this
system
• Installation and use must comply with existing state or local
plumbing codes
• Protect filter from freezing. Drain filter when room temperature
drops below 4.4
C
o
• Contact plumbing professional if you are uncertain how to check
your water pressure
• Do not install where water hammer conditions may occur. If water
hammer conditions exist you must install a water hammer arrester.
Contact a plumbing professional if you are uncertain how to check
for this condition
Treatment and Tests – Table C1
This appliance meets the domestic water treatment appliance Standards AS/NZS 3497 and AS/NZS 4348 for the following water treatment process.
Class
Treatment Type
I
Microbiological Status Will stop
bacteria increasing, but will n/a
Bacteriostatic
II
Microbiological Treatment
II (a)
Bacteria Removal
II (b)
Virus Removal
II (c)
Protozoa Removal
III
Turbidity & Particulate Reduction
IV
Taste & Odour Reduction
V
Chemical Treatment
Legend:
= Pass Test N/A = Not applicable
4
Note: the use of this appliance may increase the bacterial content of the water unless supplementary treatment is provided.
Maintenance
Avg. Influent
NSF/ANSI Specified Challenge
Concentration
2.0 mg/L
2.0 mg/L ± 10%
132,489 litres
12.6 lpm
172-862 kPa (25-125 psi)
4.4 – 38 ºC
Function
Will stop bacteria increasing, but will not remove them
unless II (a) is ticked
Will remove inactive bacteria
Will remove inactive virus
Will reduce cloudiness
Will reduce taste and odour
Will decrease chlorine compounds
Avg. %
Avg.
Reduction
Product Water
Concentration
96.6
0.07 mg/L
Testing Condition: pH: 7+/-1
Temp: 20+/-5 Celsius
Pressure: 600 kPa +/- 100 kPa
Note that while the testing was performed under standard laboratory
conditions, actual performance may vary. Systems must be installed
and operated in accordance with manufacturer's recommended
procedures and guidelines. Failure to dosomay void warranty. See
Warranty Card for Details. Caution: This filter system or cartridge is
designed to be installed on the Cold water line. Do not install on Hot
water line.
• Install on cold water lines only. Do not install on hot water supply
lines. The maximum operating water temperature of this filter
system is 38⁰C
• The disposable filter cartridge must be replaced every 12 months
or at the specified service cycle, whichever comes first
• Do not install near water pipes which will be in path of a drilling
tool when selecting the position to mount the bracket
• Mount filter in such a position as to prevent it from being struck by
other items used in the area of installation (waste baskets, etc.)
Note: Zip filter systems are designed for ease of installation.
However, post-installation inspections are highly recommended.
Check for leaks immediately after installation and once again after 24
hours. If leaks are detected, turn off water supply, drain water and
inspect the leaks. If problem persists, contact the installer / plumber
for rectification.
It is essential that operational, maintenance and filter replacement
requirements be carried out for this product to perform as advertised.
Flush new cartridge for at least 2 minutes to remove trapped air
bubbles.
If left unused for more than 24 hours, flush cartridge for 2 minutes
before use.
Pass
n/a
n/a
n/a
n/a
n/a
4
4
805812NZ v1.04 05.20 HydroChill Install Instructions
NSF Reduction
NSF Test
Requirements
Report
≥ 50%
J-00089365
33

Advertisement

Table of Contents