Step 1 – Install the Tap Font
In addition to normal tools, a 50mm diameter hole saw is required
(not supplied).
Double-check all sizes and positioning before cutting. Install only
with the new hose-sets supplied.
• Position the tap font on the benchtop. Position the centre of the
drip tray directly below the font outlet taps.
• Mark and cut the 50 mm font hole.
• Pass the font hoses through the 50 mm hole. Fit the rubber
base seal (supplied) to the base of the tap font to seal it on the
benchtop. Secure the font from under the bench with the washer
and nut.
Option - Recessed drip tray (part no 94742NZ):
• Cut the drip tray hole as shown in the diagram below.
• The drip tray rim should fit flush with the bench top. For a
watertight seal, run a bead of silicone around the outside edge of
the drip tray.
• Fit a 13mm ID drain hose (not supplied) to the outlet of the drip
tray and run with a constant fall to a drain point.
300 mm