Warnings And Precautions - Zenith HydroChill HCF90NZ Installation Instructions & User Manual

Table of Contents

Advertisement

1. All installation and service work must be completed by trained and suitably qualified
tradespeople. Faulty operation due to unqualified persons working on an Zenith product
may void warranty coverage.
2. All plumbing and electrical connections must be made in accordance with local
regulations and relevant standards including Plumbing Standard AS/NZS 3500 & Electrical Wiring Rules
AS/NZS 3000.
3. Check that the voltage shown on the chiller data plate corresponds to the voltage supplied at the
installation site.
4. The electrical circuit must be correctly earthed and connected by means of suitable differential safety
breaker. A 240V, 10 amp electrical power outlet is required.
5. If the electrical supply cord is damaged, it must be replaced by a qualified technician. To avoid hazards,
all installation procedures must be carried out by a suitably qualified tradesperson. When replacing
components, use only genuine parts certified by Zenith.
6. This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety. For products
sold in Europe, this appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand the
hazards involved. Children should be supervised to ensure that they do not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
7. The appliance contains R134a refrigerant. Refer to the compressor label inside the machine, and the
nameplate. Maintenance of the refrigeration unit must be carried out by an accredited service provider
or qualified refrigeration technician.
8. Take care when lifting. If you feel this is beyond your personal capabilities, please seek assistance with
the lift. Do not lift the appliance by the front cover or any of its connections. Refer to the Technical
specification for the weight of the product.
9. Do not locate near, or clean with water jets. Ensure that this product is not sited close to sources of
heat.
10. The product is designed to function in environments with temperature between 5°C - 32°C (Climate
Class N). The system will operate satisfactorily only if the recommended air gaps of 100 mm above, at
the back and on each side are provided. If a vent kit is supplied it must be fitted.
11. If the product is exposed to temperatures below 0°C, the water inside it may freeze and cause damage
to the product itself.
12. This appliance is designed for indoor use and must not be installed outdoors or exposed to the
elements of nature.

WARNINGS AND PRECAUTIONS

805812NZ v1.04 05.20 HydroChill Install Instructions
!
03

Advertisement

Table of Contents
loading

Table of Contents