Stove Disassembly

If there is ever a need to remove the firebox assembly
from the stove shell, support the firebox with solid
stands about 6" (152mm) tall under the left and right
outer edges of the firebox base. Do not set the firebox
assembly directly on the floor; this can damage the
control valve and/or the gas lines from the valve to the
firebox.
Before removing the firebox from the shell, disconnect
the on/off switch wires from the valve. If the assembly
includes the optional fan, disconnect the fan rheostat. If
the installation includes a wall thermostat, disconnect
the thermostat leads from valve.
Disconnection and reconnection to the gas line should
only be done by a qualified gas service technician.
Upon reinstallation, the vent system must be sealed to
the firebox as shown in the installation section, page
14. Also be sure the logs are placed in the firebox
correctly, as shown in Page 25, Figures 43-44.

Wiring Diagrams

On/Off Switch
Wiring
TP/TH
TP
TH
Optional Thermostat
Wiring
TP/TH
TP
TH
Fig. 70 PDV20/SDVR on/off switch and optional thermostat
circuit.
NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-
PLIED WITH THE APPLIANCE, MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE SF-
2, 200°C WIRE OR ITS EQUIVALENT.
38
ON
OFF
Black
ST124b
Thermostat
(Optional)
Black
ST124c
POWER
CORD
Chassis
GRN
Ground
FAN JUNCTION BOX
Strain Relief
GRN
Chassis Ground
MOTOR
BLK
ON/OFF
RHEOSTAT
Fig. 71 PDV20/SDVR fan circuit.
FAN
WHT
BLK
BLK
ON / OFF
Rheostat
Snapstat
WHT
BLK
RHEOSTAT / SNAPSTAT
BOX
ST153
Schematic Diagram
BLK
SNAPSTAT
WHT
ST234
20007066