Redback® A 4595A School Lockdown Controller

1.5 REAR PANEL CONNECTIONS

Fig 1.5A shows the layout of the A 4595A rear panel.
DIP Switch Settings
IMPORTANT NOTE
SW
On
O
Ensure power is switched o when
1
Loop MP3
Play MP3 once
adjusting DIP switches. New
24V DC
24V DC
settings will be e ective when
2-8
Not Used
IN
IN
power is switched back on.
DIP Switches
1
2
3
4
5
6
7
8
+ _
Micro SD Card
-
+
1 2 3 4 5 6 7 8
(16GB Maximum)
23
22
21
1
All Clear 24V Out
This is a 24V DC output which is activated when the All Clear Mode is triggered. The terminals provided can be
used for "Normal" or "Failsafe" modes (see section 3.5 for more details).
2
Lock In 24V Out
This is a 24V DC output which is activated when the Lock In Mode is triggered. The terminals provided can be
used for "Normal" or "Failsafe" modes (see section 3.5 for more details).
3
Standby 24V Out
This is a 24V DC output which is activated when the Standby Mode is triggered. The terminals provided can be
used for "Normal" or "Failsafe" modes (see section 3.5 for more details).
4
Lock Out 24V Out
This is a 24V DC output which is activated when the Lock Out Mode is triggered. The terminals provided can be
used for "Normal" or "Failsafe" modes (see section 3.5 for more details).
5
Bell/Pre-Bell 24V Out
This is a 24V DC output which is activated when the Bell or Pre-Bell tone is triggered. The terminals provided can
be used for "Normal" or "Failsafe" modes (see section 3.5 for more details).
6
Common 24V Out
This is a combined 24V DC output which is activated when any of the Bell, Pre-Bell, Standby, Lock In, Lock Out,
All Clear, Aux MP3-1, Aux MP3-2 or Aux MP3-3 tones are activated or when paging is active. The terminals
provided can be used for "Normal" or "Failsafe" modes (see section3.5 for more details).
7
Emergency 24V Out
This is a 24V DC output which is activated when the Standby, Lock In, Lock Out and All Clear tones are activated
or when Emergency paging is active. The terminals provided can be used for "Normal" or "Failsafe" modes (see
section 3.5 for more details).
8
RJ45 connectors for Wall Plates
These RJ45 ports connect to the wall plates. A Maximum of 16 plates is recommended, (If more than 16 wall
plates are required contact Altronics for configuration details).
9
RJ45 connectors for Paging Consoles
These RJ45 ports connect to the paging consoles. A Maximum of 4 paging consoles is recommended.
10
MP3 Volume
Adjust this trimpot to adjust the MP3 tones volume.
11
Master Volume
Adjust this trimpot to adjust the master volume.
6
Redback® Proudly Made In Australia
1
2
All Clear
Lock In
Contacts
24V Out
24V Out
All switched outputs limited to 120mA maximum current draw
16
18
15
20
19
17
3
4
5
6
7
Standby
Lock Out
Bell/Pre-Bell
Common
Emergency
24V Out
24V Out
24V Out
24V Out
24V Out
Interface 1
Interface 2
14
Fig 1.5A
8
9
10 11 12
1
2
1
2
3
4
3
4
Mp3
Master
To Paging Consoles
To Wall Plates
Volume
Volume
13
www.altronics.com.au
L
Made in Australia by
Altronic Distributors
R
Pty Ltd
www.redbackaudio.com.au
Audio
Out