A 4598 And A 4598V Overview - Redback A 4595A Operating Manual

School lockdown controller
Table of Contents

Advertisement

Redback® A 4595A School Lockdown Controller
4.2 A 4598 & A 4598V Lockdown Remote Plates
The A 4598 wall plate allows a remote means of triggering the Standby, Lock In, Lock Out and All Clear modes. The
switches are momentary operation and must be pressed for up to 3 seconds to activate. The switches have protective "flip
up" covers to prevent accidental operation.
Connection is made to the A 4595A via standard Cat5e cabling as shown in figure 4.2B. There are two RJ45 ports on the
rear of the A 4598 and A 4598V wall plates, either of which can be used.
NOTE: The All Clear switch doubles as a Cancel switch. Pressing the switch when the unit is in "All Clear" mode will
cancel the "All Clear" mode.
20
Redback® Proudly Made In Australia
A 4598
A 4598V
CASCADING THE A 4598 PLATES
If more than one remote wall plate is required then the
A 4598 and A 4598V wall plates can be connected back
to the A 4595A using any of the four RJ45 ports supplied.
If more than four wall plates are required then they can be
cascaded together back to the A 4595A as shown in figure
4.2B.
A Maximum of 16 combined wall plates (A 4598, A 4598V
or A 4597) is recommended, but up to 63 wall plates can be
connected.
(If more than 16 wall plates are required contact Altronics for
configuration details).
Every wall plate must have a unique ID which is set by the
DIP switches which are accessed on the rear of the unit. A
maximum of 63 ID's are available. Fig 4.2A illustrates the DIP
switch ID settings.
DIP Switches 7-8 are not used.
DIP Switch Settings
ID
1
2
3
4
5
6
1
ON
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
10
OFF
ON
OFF
ON
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
12
OFF
OFF
ON
ON
OFF
OFF
13
ON
OFF
ON
ON
OFF
OFF
14
OFF
ON
ON
ON
OFF
OFF
15
ON
ON
ON
ON
OFF
OFF
16
OFF
OFF
OFF
OFF
ON
OFF
17
ON
OFF
OFF
OFF
ON
OFF
18
OFF
ON
OFF
OFF
ON
OFF
19
ON
ON
OFF
OFF
ON
OFF
20
OFF
OFF
ON
OFF
ON
OFF
21
ON
OFF
ON
OFF
ON
OFF
22
OFF
ON
ON
OFF
ON
OFF
23
ON
ON
ON
OFF
ON
OFF
24
OFF
OFF
OFF
ON
ON
OFF
25
ON
OFF
OFF
ON
ON
OFF
26
OFF
ON
OFF
ON
ON
OFF
27
ON
ON
OFF
ON
ON
OFF
28
OFF
OFF
ON
ON
ON
OFF
29
ON
OFF
ON
ON
ON
OFF
30
OFF
ON
ON
ON
ON
OFF
31
ON
ON
ON
ON
ON
OFF
32
OFF
OFF
OFF
OFF
OFF
ON
Fig 4.2A
DIP Switch Settings
ID
1
2
3
4
5
6
33
ON
OFF
OFF
OFF
OFF
ON
34
OFF
ON
OFF
OFF
OFF
ON
35
ON
ON
OFF
OFF
OFF
ON
36
OFF
OFF
ON
ON
OFF
OFF
37
ON
OFF
ON
OFF
OFF
ON
38
OFF
ON
ON
ON
OFF
OFF
39
ON
ON
ON
ON
OFF
OFF
40
OFF
OFF
ON
OFF
ON
OFF
41
OFF
ON
ON
OFF
ON
OFF
42
OFF
ON
OFF
ON
OFF
ON
43
ON
ON
OFF
ON
OFF
ON
44
OFF
OFF
ON
ON
OFF
ON
45
ON
OFF
ON
ON
OFF
ON
46
OFF
ON
ON
ON
OFF
ON
47
ON
ON
ON
ON
ON
OFF
48
ON
OFF
OFF
OFF
OFF
ON
49
ON
OFF
OFF
OFF
ON
ON
50
ON
OFF
ON
OFF
OFF
ON
51
ON
ON
OFF
OFF
ON
ON
52
OFF
OFF
ON
ON
OFF
ON
53
ON
OFF
ON
OFF
ON
ON
54
OFF
ON
ON
OFF
ON
ON
55
ON
ON
ON
OFF
ON
ON
56
OFF
OFF
OFF
ON
ON
ON
57
ON
OFF
OFF
ON
ON
ON
58
OFF
ON
OFF
ON
ON
ON
59
ON
ON
OFF
ON
ON
ON
60
ON
OFF
OFF
ON
ON
ON
61
ON
OFF
ON
ON
ON
ON
62
OFF
ON
ON
ON
ON
ON
63
ON
ON
ON
ON
ON
ON
www.altronics.com.au

Hide quick links:

Advertisement

Table of Contents
loading